Features

  • Fully welded metal measuring cell
  • Pressure range 0…25 bar rel.
  • Pressure peak orifice
  • Process connection 1/4"-18 NPT male thread
  • Plug-in device, M12 × 1

Functional principle

The pressure sensors in the PT…‐2000 product series operate with a fully welded metal measuring cell in various pressure ranges of up to -1…1000 bar in 2-, 3- or even 4-wire technology. Depending on the sensor variant, the processed signal is available as an analog output signal (4…20 mA, 0… 10 V, 0…5 V, 1…6 V, ratiometric) or as a digital IO-Link process parameter. The IO-Link sensor variants also have two independently configurable switching outputs. In addition to the standard variants, there are special sensors for uses such as ATEX areas or for oxygen applications. A wide range of process connections and electrical connections offer a high degree of flexibility in a wide range of applications.

Mechanical data

Material pressure transducer Stainless steel 1.4016 (AISI 430)
Elektrischer Anschluss Connector, M12 × 1
Process connection 1/4'' NPT-18 male thread
Pressure connection material Stainless steel 1.4404 (AISI 316L)
Max. tightening torque of housing nut 20 Nm
Housing material Stainless-steel/Plastic, 1.4404 (AISI
Housing material 316L)/polyarylamide 50 % GF UL 94 V-0

Allgemein

Pressure range from 0 to 25 bar
Pressure type Relative pressure
Bursting pressure from 150 bar
Long-term stability 0.25 % FS, according to IEC EN 60770-1
Admissible overpressure up to 75 bar
Ansprechzeit (bei ruhender Luft) < 2 ms, typ. 1 ms

Reference conditions acc. to IEC 61298-1

Auxiliary power 24 VDC
Humidity from 45 to 75 %
Atmospheric pressure from 860 to 1060 hPa
Temperatur (-) 15…+25 °C

Power supply

Short-Circuit/Reverse Polarity Protection yes / yes
Degree of protection (IP) IP67
Electrical safety class III

Ambient Conditions

Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude ± 15 mm, 1 octave/minute in all 3
Vibration resistance directions, 50 continuous loads, acc. to
Vibration resistance IEC 68-2-6
Ambient temperature from -30 to 85 °C
Storage temperature from -50 to 100 °C
Shock resistance 100 g, 11 ms, half sinusoidal curve, all
Shock resistance 6 directions, free fall from 1 m onto concrete (6x) acc. to IEC 68-2-27

Output

Accuracy LHR ±0.3 % FS (typical; max. ±0.5 % FS)
Resolution <± 0.1 % FS

Temperature behaviour

Temperature coefficient (zero point) ± 0.2 % of full scale/10 K
Medium temperature from -40 to 135 °C

Tests/approvals

UL registration number E302799
Approvals cULus