HomeProcess SensorsPressure Sensors100000753
Turck Pressure Transmitter – Ratiometric Output (3-Wire) – Image 1
Turck

Pressure Transmitter – Ratiometric Output (3-Wire)

SKU: 100000753 Type: PT600R-2104-U6-AMP3J1
Available 3–5 business days delivery
€138.10 / pieces
€164.34 incl. VAT
Data sheet

Features

  • For mobile hydraulic applications
  • Fully welded metal measuring cell
  • Sealless
  • With pressure tip orifice
  • Compact and robust design
  • Excellent EMC properties
  • Excellent accuracy and long-term stability
  • Kfz-Norm ISO 16750
  • Pressure range 0…600 bar rel.
  • 5 VDC ± 10 %
  • Ratiometric output 10…90 %
  • Process connection G1/4'' male thread (back sealing) according to DIN EN ISO 1179-2 with FPM profile sealing ring
  • Connector device, AMP JPT

Functional principle

The pressure sensors in the PT…‐2100 product series are designed specifically for demanding mobile hydraulic applications. They operate with a fully welded metal measuring cell in different pressure ranges of up to 0…600 bar in 2- or 3-wire technology. Depending on the sensor variant, the processed signal is available as an analog output (4…20 mA, 0…10 V, 0…5 V, ratiometric). A wide range of process connections and electrical connections offer a high degree of flexibility in many different applications.

Mechanical data

Material pressure transducer Stainless steel 1.4404 (AISI 316L)
Elektrischer Anschluss Connector, AMP JPT
Process connection G1/4'' male thread (back sealing) according to DIN EN ISO 1179-2 with FPM profile sealing ring
Pressure connection material Stainless steel 1.4404 (AISI 316L)
Max. tightening torque of housing nut 20 Nm
Housing material Stainless-steel/Plastic, 1.4404 (AISI
Housing material 316L)/polyarylamide 50 % GF UL 94 V-0

Allgemein

Pressure range from 0 to 600 bar
Pressure type Relative pressure
Bursting pressure from 2500 bar
Long-term stability 0.3 % FS, acc. to IEC EN 61298-2
Admissible overpressure up to 1500 bar
Ansprechzeit (bei ruhender Luft) < 2 ms, typ. 1 ms

Analog output

Load ≤ 100 nF/> 10 kΩ
Accuracy LHR ±0.5 % FS (under EMC interference max.
Accuracy LHR ±1.5 % FS)
Voltage output from 0.5 to 4.5 V

Reference conditions acc. to IEC 61298-1

Auxiliary power 24 VDC
Humidity 45 % rel.
Atmospheric pressure from 860 to 1060 hPa
Temperatur (-) 15…+25 °C

Ambient Conditions

EMC Interference Immunity/Interference Emission
EMC EN 61326-2-3 - Pressure transducer
EMC ISO 13766 - Earthmoving machinery
EMC DIN EN 13309 - Construction machinery
EMC DIN ISO 14982 - Forestry and agriculture
EMC CISPR11
EMC Immunity Motor Vehicle Directive
EMC ISO 11452-2, HF (Field), 100 V/m (200…
EMC 2000 MHz)
EMC ISO 11452-4, HF (BCI), 100 mA (20…
EMC 400 MHz)
EMC ISO 10605, ESD, ±15 kV contact, ±15 kVair
EMC ISO 7637-2 3), pulses 1, 2a, 2b, 3a, 3b
EMC (test level 4)
EMC ISO 16750-2, load dump, 155 V (1 Ω, 300
EMC ms)
EMC Motor vehicle directive ECE R10
EMC Motor vehicle directive 2004/104/EC
Vibration resistance Test VI (12 g, sinusodial 18 g random vibration)
Ambient temperature from -40 to 100 °C
Storage temperature from -50 to 100 °C
Shock resistance 50 g, 11 ms, half sine curve, 1000x/axis acc. to ISO 16750-3

Power supply

Short-Circuit/Reverse Polarity Protection yes / yes
Insulation voltage 500 VDC
Electricity consumption up to 7 mA
Operating voltage UB from 4.5 to 5.5 VDC
Degree of protection (IP) IP67
Electrical safety class III

Tests/approvals

MTTF 1564 years acc. to SN 29500 (Ed. 99) 40
MTTF °C
Included in delivery Profile seal FKM special (1 pc)
UL registration number E302799
Approvals cULus

Temperature behaviour

Temperature coefficient (zero point) ± 0.2 % of full scale/10 K
Medium temperature from -40 to 125 °C

Output

Output function ratiom. 10…90%
Output 1 Analog output