HomeProcess SensorsHumidity Sensors100016580
Turck Humidity and Temperature Sensor For Condition Monitoring with IO-Link – Image 1
Turck

Humidity and Temperature Sensor For Condition Monitoring with IO-Link

SKU: 100016580 Type: CMTH-M12-IOL6X2-H1141
Available 3–5 business days delivery
€142.00 / pieces
€168.98 incl. VAT
Data sheet

Features

  • Sensor for condition monitoring
  • Accurate temperature and humidity measurement
  • Sensor-2-cloud compatible
  • DC 4-wire, 18…30 VDC
  • M12 × 1 male connector
  • Configuration and communication via IOLink v1.1
  • Smart sensor profile 4
  • Continuous process values for temperature and humidity
  • Temperature monitoring with adjustable switching thresholds or windows
  • Humidity monitoring with adjustable switching thresholds or windows
  • Operating hours and switching threshold counter
  • Dew point calculation and output as well as temperature and humidity histogram via IO-Link

Functional principle

Condition monitoring sensors are specially designed for use in system parts in which the environmental parameters can have a significant influence on machine availability or process quality. By monitoring the application temperature or the humidity within the application, process deviations can be detected at an early stage and countermeasures initiated. For this purpose, the continuous detection value is transferred to the controller via IO-Link process data and customer-specific limit value exceedance/shortfall is additionally transported. The robust sensor design can be used indoors as well as outdoors for more challenging applications.

Electrical data

DC rated operating current Ie ≤ 150 mA
No-load current I0 ≤ 10 mA
Adjustment option IO-Link
max. load current Io 50 mA
Short circuit protection yes/Cyclic
Polarity protection yes
Output function Programmable, IO-Link
Output 2 Switching output
Residual ripple < 10 % Uss
Operating voltage UB from 18 to 30 VDC
Ansprechzeit (bei ruhender Luft) RH % (t63) 6 s

IO-Link

Maximum Cable Length 20 m
IO-Link port type Class A
Communication mode COM 3 (230.4 kBaud)
Function pin 4 IO-Link
Function Pin 2 SIO
Frame type 2.2
Process data width 64 bit
Minimum cycle time 10 ms
Profile support Smart Sensor Profile
Switchpoint information 4 bit
IO-Link specification V 1.1
Measured value information 24 bit

Mechanical data

Display operating voltage LED, Green
Elektrischer Anschluss Connector, M12 × 1
Pressure resistance 10 bar
Ambient temperature from -40 to 100 °C
Storage temperature from -40 to 100 °C
Design Cylinder, threaded, M12
Housing material Metal, CuZn, Chrome-plated
Degree of protection (IP) IP67
Abmessung Ø 12 x 57 mm

Tests/approvals

EMC EN 61326-1
Vibration resistance IEC 60060-2-6: (10…150 Hz) 20 g
MTTF 610 years
Shock test IEC 60068-2-27: 50 g (6 ms)
Approvals cULus
Approvals CE

General data

Resolution — relative humidity 0.1 % rH
Function Temperature/humidity sensor
Resolution — temperature 0.1 K
Repeatability 0.2 °C
Accuracy ±0.8 °C
Accuracy ±5 % RH (10…90 % RH)
Accuracy ±7 % RH (0…10 % RH/90…100 % RH)
Measuring range -40…100 °C
Measuring range -40…212 °F
Measuring range 0…100 % RH