Radio Transmission System – Tree Topology Teilnehmer mit RS485-Schnittstelle
Features
- • External antenna (RG58 RP-SMA connection)
- • Integrated signal strength indicator
- • Configuration via DIP switch
- • Modbus RTU (RS485)
- • Self-organizing tree structure
- • Repeater for extension of network
- • Deterministic data transfer
- • Frequency hopping FHSS
- • Time Division Multiplex Access TDMA
- • Transmission power: 63 mW, 18 dBm conducted, ≤ 20 dBm EIRP
- • Inputs: 4 x RTD (PT100 / PT1000)
Functional principle
The DX80 Data Radios are self-organizing. They create a network in tree topology. They transfer Modbus RTU telegrams or other data from other bus systems. The telegrams are routed through the network and lost radio communication is compensated via alternative routes. Further sensors can be added to the network and their data is accessible via internal registers. Each network consists of a master and an unlimited number of repeaters or slaves. The device type is adjusted via DIP switch. This system can be combined with several DX80 networks to transfer data from the DX80 gateway via Modbus RTU to the control system. Directives: FCC‐ID UE300DX80‐2400. This device complies with FCC para. 15, subpara. C, 15.247 ETSI/EN: In compliance with EN 300 328: V1.8.1 (2014‐04) IC: 7044A‐DX8024 Radiation protection 10 V/m for 80-2700 MHz acc. to EN 61000-6-2 Shock and vibration resistant: IEC 68-2-6 and IEC 68-2-7
Wireless data
| Topology | Star topology |
| Spread spectrum technology | FHSS (Frequency Hopping Spread Spectrum) |
| Device type | Node |
| Response time typical | < 1000 ms |
| Function | Tree topology |
| Channel width | 1 MHz |
| Output power ERP | 18 dB/65 mW |
| Range | 3200000 mm |
| Installation | stationary |
| Type of radio | short-range |
| Number of radio channels | 50 |
| Single-Carrier Residence Time | 7.8 ms |
| Frequency band | 2.4-GHz ISM band |
| Frequency range | from 2402000000 to 2483000000 Hz |
| Output power EIRP | 20 dB/100 mW |
Electrical data
| Display operating voltage | LED, Green |
| Battery solution | Yes |
| Operating voltage UB | from 3.6 to 5.5 VDC |
Tests/approvals
| Device designation | II 3 G Ex nA IIC T4 Gc |
| Approvals | ATEX |
| Approvals | CE |
| Approvals | CSA |
| Ex approval acc. to conformity certificate | LCIE 10 ATEX 1012 X |
I/O data
| Number of channels | 4 |
| Number of channels | - |
| Output type | - |
| Input type | RTD |
| Communication protocol | RS485 |
| Communication protocol | Modbus RTU |
Mechanical data
| Ambient temperature | from -20 to 80 °C |
| Antenna connection | RP-SMA female connector |
| Design | Rectangular, DX80DR |
| Housing material | Plastic, PC |
| Degree of protection (IP) | IP67 |
| Abmessung | 127 x 80.8 x 57 mm |
-
– Accessories Surge Protection3079296 -
– Connection Accessories Antenna Cable3078544 -
– Connection Accessories Antenna Cable3078337 -
– Connection Accessories Antenna Cable3078338 -
– Connection Accessories Antenna Cable3077488 -
– Connection Accessories Antenna Cable3077486 -
– Connection Accessories Antenna Cable3077820 -
– Connection Accessories Antenna Cable3077489 -
– Connection Accessories Antenna Cable3077490 -
– Connection Accessories Antenna Cable3077821 -
– Connection Accessories Antenna Cable3077822 - Y-piece with cable, 1 × M12 × 1 female connector to 2 × M12 × 1 male connector; for separate supply of DX80 radio components when connected to the PC via USB adapter6634679
- Converter cable, RS485 to USB 2.0 converter, female connector, M12 × 1, 5-pin, male connector, USB type A, length 1 m; supplies the connected device with 10 V. An external power supply via a Y-splitter (6634679) is recommended for the connected device3081325
-
– Accessories USB-RS485 Converter3019970
-
Antenna3081081 -
Antenna3081080 -
Antenna3077816 - Antenna3077817
- Antenna3077818