| Travel speed | 3 m/s @ 25 °C |
| Material property (jacket) | abrasion-resistant, low adhesion, good machinability, matte |
| Freedom from ingredients (jacket) | lead-free, cadmium-free, CFC-free, halogen-free, silicone-free |
| Voltage Withstand | 2.5 kV @ 60 s |
| Withstand voltage (wire - wire) | 2.5 kV @ 60 s |
| Torsional stress | ± 180 °/m |
| Outer diameter insulation | 1,25 mm |
| Shore hardness jacket | 90 ± 5 Shore A |
| Tolerance outer diameter (sheath) | ± 5 % |
| Stranding | 1 × 3 wires stranded |
| Conductor type (wire) | strand class 6 |
| Outer-diameter (jacket) | 4.1 mm |
| Torsion speed | 35 cycles/min |
| Bending radius (flexible) | 5 × Outer diamete |
| Cable type | 3 |
| Amount strands (wire) | 32 wire |
| Shore hardness wire insulation | 70 ± 5 Shore D |
| Traversing distance (C-track) | 10 m @ 25 °C | hor |
| Material jacket | PUR |
| Conductor resistance (wire) | 79 Ω/km @ 20 °C |
| Material conductor wire | Stranded copper wire, bare |
| Ingredient freeness wire insulation | lead-free, cadmium-free, CFC-free, halogen-free, silicone-free |
| Conductor crosssection (wire) | 0.25 mm² |
| Current load capacity (standard) | to DIN VDE 0298-4 |
| Cable identification | 630 |
| Diameter of single wires | 0,1 mm |
| Min. operating temperature (static) | -40 °C |
| Nominal voltage max. | 300 V |
| Acceleration (max.) | 10 m/s² @ 25 °C |
| Cable weigth | 24 g/m |
| Material wire insulation | PP |
| Other resistances | good resistance to gasoline, resistant to hydrolysis, resistant to microbes |
| Max. operating temperature (fixed) | 80 °C / 90 °C @ 10 |
| Chemical resistance | good |
| No. of bending cycles (C-track) | 10 Mio. @ 25 °C |
| Amount wires | 3 |
| No. of torsion cycles | 2 Mio. |
| Flame resistance | UL 1581 § 1090, CSA FT2, IEC 60332-2-2 |
| Wire arrangement | brown, black, blue |
| Oil resistance | IEC 60811-404 |
| Operating temperature max. | 80 °C / 90 °C @ 10000 h Operation |
| Operating temperature min. | -25 °C |
| Current load capacity max. (wire) | up to 4.5 A |