HomeAccessoriesConnectors100051431
Turck Frequency Transducer/Pulse Counter 1-channel IM12-FI01-1SF-1I1R-C0/24VDC/K71 – Image 1
Turck

Frequency Transducer/Pulse Counter 1-channel IM12-FI01-1SF-1I1R-C0/24VDC/K71

SKU: 100051431 Type: IM12-FI01-2SF-1I1R-C0/24VDC/K71
Available 3–5 business days delivery
€296.90 / pieces
€353.31 incl. VAT
Data sheet

Features

  • Input circuits monitored for wire break and short circuit
  • Parameterized via PC
  • Complete galvanic isolation
  • Removable screw terminals

Output circuits

Switching current per output ≤ 2 A
Contact quality AgNi
Output current Source/sink (10…30 V) 0/4…20 mA
Switching capacity per output ≤ 500 VA/60 W
Switching frequency up to 15 Hz
Load resistance current output ≤ 0.8 kΩ
Output circuits 1 x relay (change-over)
Output switching voltage relay ≤ 30 VDC / ≤ 250 VAC

NAMUR input

Wire breakage threshold ≤ 0.06 mA
Switch-on threshold 1.75 mA
Short-circuit current 8.2 mA
Input resistance 1 kΩ
Switch-off threshold 1.55 mA
Short-circuit threshold ≥ 6.4 mA
No-load voltage 8.2 VDC
NAMUR EN 60947-5-6
Line Resistance ≤ 50 Ω

Displays/Operating elements

Operational readiness Green
Error indication red

Allgemein

Monitoring range/Setting range 0.0006…1,200,000 rpm
Nominal voltage 24 VDC
Operating voltage UB from 10 to 30 VDC
Power consumption up to 3 VA

Galvanic separation

Test voltage 2.5 kV RMS
A1A-A1D 300 V RMS acc. to EN 50178 and EN 61010-1
E1,E2-E3 375 V peak value acc. to EN 60079-11
E1,E2 supply voltage 375 V peak value acc. to EN 60079-11
E3 supply voltage 375 V peak value acc. to EN 60079-11
A1A-E3 300 V RMS acc. to EN 50178 and EN 61010-1
A1A supply voltage 300 V RMS acc. to EN 50178 and EN 61010-1

3-wire input

1-signal 5...30 VDC
0-signal 0...3VDC
No-load voltage 12 VDC

External signal source

1-signal 5…30 VDC
0-signal 0…3 VDC

Response characteristic

Temperature drift ≤ 0.0025 % of full scale/K
Reference temperature 23 °C

Mechanical data

Altitude Up to 2000 m above sea
Altitude level
Pollution degree II
Overvoltage category II (EN 61010-1)