Turck

Turck
Miniature Encoder – With Analog Output Premium Line
SKU: 100000197 Type: RI60P1-QR20-LU4X2-0.24-AMP01-3P
Available3–5 business days delivery
€113.70 / pieces
€135.30 incl. VAT
These are our list prices.Get an individual quote within 24 h.
Request a quoteFeatures
- Rectangular, plastic
- Compact and robust housing
- Versatile mounting possibilities
- Positioning element P1-RI-QR20 included in delivery
- For vehicle board nets, 12 V and 24 V
- Increased interference immunity 100 V/m following the e1 type approval
- Protection against conducted interference acc. to DIN ISO 7637-2 (SAE J 113-11)
- Extended temperature range
- High protection class IP68/IP69K
- Protection against salt spray and rapid temperature changes
- Measuring range displayed via LED
- Immune to electromagnetic interference
- Resolution: 0.09°
- 3‐wire, 8…30 VDC
- Analog output 0.5…4.5 V
- Output 5 V (typ.) where there is no RLC coupling
Functional principle
These sensors are extremely reliable even under the most extreme environmental conditions. Their extremely robust design meets the requirements for the IP68 and IP69K protection ratings. Thanks to their excellent resistance to constant shocks and thermal shock resistance, they are the ideal choice for mobile applications, such road construction vehicles and agricultural machinery.
Mechanical data
| Shaft type | Blind hole shaft |
| Shaft diameter D | 6 6.35 |
| Elektrischer Anschluss | Cable with connector, AMP Superseal |
| Cable quality | Ø 5.2 mm, Lif32Y32Y, TPE, 0.24 m |
| Design | Rectangular, QR20 |
| Flange type | Flange without mounting element |
| Core cross-section | 3 x 0.5 mm2 |
| Housing material | Plastic, Ultem |
| Abmessung | 71.6 x 62.6 x 20 mm |
Electrical data
| Wire break/reverse polarity protection | no/yes (voltage supply) |
| Diagnostics | Positioning element not detected: Output |
| Diagnostics | signal 5 V |
| Isolation test voltage | 0.5 kV |
| Load resistance voltage output | ≥ 4.7 kΩ |
| Electricity consumption | up to 100 mA |
| Sampling rate | 800 Hz |
| Short circuit protection | yes |
| Output function | 3-wire, Analog output |
| Load-dump protection (DIN ISO 7637-2) | Severity degree IV/Level 4 |
| Ripple Uss | ≤ 10 % UBmax |
| Operating voltage | from 8 to 30 V |
| Voltage output | from 0.5 to 4.5 V |
Ambient Conditions
| Continuous shock resistance (EN 60068-2-29) | 40 g; 6 ms ½ Sinus; je 4000 x; 3 Achsen |
| Display operating voltage | LED, Green |
| Vibration resistance | 55 Hz (1 mm) |
| Vibration resistance | 20 g; 10…3000 Hz; 50 Zyklen; 3 Achsen |
| MTTF | 423 years acc. to SN 29500 (Ed. 99) 40 |
| MTTF | °C |
| Included in delivery | Positioning element P1-RI-QR20; for |
| Included in delivery | technical details see data sheet |
| Salt spray test (EN 60068-2-52) | Severity degree 5 (4 test cycles) |
| Ambient temperature | from -40 to 85 °C |
| Temperature changes (EN60068-2-14) | -40… +85 °C; 20 cycles |
| Measuring range display | multifunction LED, green |
| Measuring range display | green flashing |
| Storage temperature | from -40 to 125 °C |
| Shock resistance | 100 g; 11 ms ½ sine; 3 × each; 3 axes |
| Degree of protection (IP) | IP69K |
| Degree of protection (IP) | IP68 |
General data
| Temperature drift | ≤ ± 0.01 %/K |
| Resolution | 0.09°/12 bit |
| Output type | Absolute singleturn |
| Nominal distance | 1 mm |
| Repeatability | ≤ 0.15 % of full scale |
| Measuring range | -30…30 ° |
| Linearity deviation | ≤ 1.25 % f.s. |
Allgemein
| Measurement principle | Inductive |
Other
| Design | Quader |
| Housing material | Kunststoff |
| Connector type | Kabel |