HomeProcess SensorsPressure Sensors100000514
Turck Pressure Transmitter – With Current Output (2-Wire) – Image 1
Turck

Pressure Transmitter – With Current Output (2-Wire)

SKU: 100000514 Type: PT40R-1003-IX-H1143
Available 3–5 business days delivery
€222.60 / pieces
€264.89 incl. VAT
Data sheet

Features

  • Ceramic measuring cell
  • Compact and robust design
  • Excellent EMC properties
  • ATEX Ex II 1/2 GD
  • FPM sealing material
  • 10…30 VDC
  • Analog output 4…20 mA
  • Process connection 1/4"-18 NPT male thread
  • Plug-in device, M12 × 1
  • ATEX, IECEx
  • Category II 1/2 GD, Ex zone 0

Functional principle

The pressure sensors in the PT…‐1000 product series operate with a ceramic measuring cell in various pressure ranges of up to -1…60 bar in 2-, 3- or even 4-wire technology. Depending on the sensor variant, the processed signal is available as an analog output signal (4…20 mA, 0…10 V, 0…5 V, 1… 6 V, ratiometric) or as a digital IO-Link process parameter. The IO-Link sensor variants also have two independently configurable switching outputs. In addition to the standard variants, there are special sensors for uses such as ATEX areas or for oxygen applications. A wide range of process connections and electrical connections offer a high degree of flexibility in a wide range of applications.

Mechanical data

Material pressure transducer Ceramic Al₂O₃
Sealing material FPM spez.
Elektrischer Anschluss Connector, M12 × 1
Process connection 1/4'' NPT-18 male thread
Pressure connection material Stainless steel 1.4404 (AISI 316L)
Max. tightening torque of housing nut 20 Nm
Housing material Stainless-steel/Plastic, 1.4404 (AISI
Housing material 316L)/polyarylamide 50 % GF UL 94 V-0

Allgemein

Pressure range from 0 to 40 bar
Pressure type Relative pressure
Bursting pressure from 120 bar
Long-term stability 0.25 % FS, according to IEC EN 60770-1
Admissible overpressure up to 120 bar
Ansprechzeit (bei ruhender Luft) < 2 ms, typ. 1 ms

Analog output

Load ≤ (supply voltage -10)/20 kΩ
Current output 4…20 mA
Accuracy LHR ±0.3 % FS (typical; max. ±0.5 % FS)
Resolution <± 0.1 % FS

Reference conditions acc. to IEC 61298-1

Auxiliary power 24 VDC
Humidity from 45 to 75 %
Atmospheric pressure from 860 to 1060 hPa
Temperatur (-) 15…+25 °C

Power supply

Short-Circuit/Reverse Polarity Protection yes / yes
Insulation voltage 750 VDC
Electricity consumption up to 23 mA
Operating voltage UB from 10 to 30 VDC
Degree of protection (IP) IP67
Electrical safety class III

Ambient Conditions

Vibration resistance 20 g, 15…2000 Hz, 15…25 Hz with amplitude ± 15 mm, 1 octave/minute in all 3
Vibration resistance directions, 50 continuous loads, acc. to
Vibration resistance IEC 68-2-6
Ambient temperature from -25 to 85 °C
Storage temperature from -50 to 100 °C
Shock resistance 100 g, 11 ms, half sinusoidal curve, all
Shock resistance 6 directions, free fall from 1 m onto concrete (6x) acc. to IEC 68-2-27

Tests/approvals

MTTF 1189 years acc. to SN 29500 (Ed. 99) 40
MTTF °C
Application area II 1/2 GD
Ignition protection category Gas Ex ia IIC; dust Ex ia IIIC
UL registration number E302799
Approvals cULus
Ex approval acc. to conformity certificate SEV 16 ATEX 0145
Important note For intrinsically safe applications, the values specified in the corresponding Ex certificates (ATEX, IECEX,
Important note UL etc.) apply.

Temperature behaviour

Temperature coefficient (zero point) ± 0.2 % of full scale/10 K
Medium temperature from -30 to 120 °C

Output

Output function Analog output current
Output 1 Analog output