HomeProcess SensorsPressure Sensors100000514
TurckPressure Transmitter – With Current Output (2-Wire) – Image 1
Turck

Pressure Transmitter – With Current Output (2-Wire)

SKU: 100000514 Type: PT40R-1003-IX-H1143
Available3–5 business days delivery
€222.60 / pieces
€264.89 incl. VAT

These are our list prices.Get an individual quote within 24 h.

Request a quote
Data sheet

Features

  • Ceramic measuring cell
  • Compact and robust design
  • Excellent EMC properties
  • ATEX Ex II 1/2 GD
  • FPM sealing material
  • 10…30 VDC
  • Analog output 4…20 mA
  • Process connection 1/4"-18 NPT male thread
  • Plug-in device, M12 × 1
  • ATEX, IECEx
  • Category II 1/2 GD, Ex zone 0

Functional principle

The pressure sensors in the PT…‐1000 product series operate with a ceramic measuring cell in various pressure ranges of up to -1…60 bar in 2-, 3- or even 4-wire technology. Depending on the sensor variant, the processed signal is available as an analog output signal (4…20 mA, 0…10 V, 0…5 V, 1… 6 V, ratiometric) or as a digital IO-Link process parameter. The IO-Link sensor variants also have two independently configurable switching outputs. In addition to the standard variants, there are special sensors for uses such as ATEX areas or for oxygen applications. A wide range of process connections and electrical connections offer a high degree of flexibility in a wide range of applications.

Mechanical data

Material pressure transducerCeramic Al₂O₃
Sealing materialFPM spez.
Elektrischer AnschlussConnector, M12 × 1
Process connection1/4'' NPT-18 male thread
Pressure connection materialStainless steel 1.4404 (AISI 316L)
Max. tightening torque of housing nut20 Nm
Housing materialStainless-steel/Plastic, 1.4404 (AISI
Housing material316L)/polyarylamide 50 % GF UL 94 V-0

Allgemein

Pressure rangefrom 0 to 40 bar
Pressure typeRelative pressure
Response timeup to 2 ms
Bursting pressurefrom 120 bar
Long-term stability0.25 % FS, according to IEC EN 60770-1
Admissible overpressureup to 120 bar

Analog output

Load≤ (supply voltage -10)/20 kΩ
Current output4…20 mA
Accuracy LHR±0.3 % FS (typical; max. ±0.5 % FS)
Resolution<± 0.1 % FS

Reference conditions acc. to IEC 61298-1

Auxiliary power24 VDC
Humidityfrom 45 to 75 %
Atmospheric pressurefrom 860 to 1060 hPa
Temperatur (-)15…+25 °C

Power supply

Short-Circuit/Reverse Polarity Protectionyes / yes
Insulation voltage750 VDC
Electricity consumptionup to 23 mA
Operating voltagefrom 10 to 30 V
Degree of protection (IP)IP67
Electrical safety classIII

Ambient Conditions

Vibration resistance20 g, 15…2000 Hz, 15…25 Hz with amplitude ± 15 mm, 1 octave/minute in all 3
Vibration resistancedirections, 50 continuous loads, acc. to
Vibration resistanceIEC 68-2-6
Ambient temperaturefrom -25 to 85 °C
Storage temperaturefrom -50 to 100 °C
Shock resistance100 g, 11 ms, half sinusoidal curve, all
Shock resistance6 directions, free fall from 1 m onto concrete (6x) acc. to IEC 68-2-27

Tests/approvals

MTTF1189 years acc. to SN 29500 (Ed. 99) 40
MTTF°C
Application areaII 1/2 GD
Ignition protection categoryGas Ex ia IIC; dust Ex ia IIIC
UL registration numberE302799
ApprovalscULus
Ex approval acc. to conformity certificateSEV 16 ATEX 0145
Important noteFor intrinsically safe applications, the values specified in the corresponding Ex certificates (ATEX, IECEX,
Important noteUL etc.) apply.

Temperature behaviour

Temperature coefficient (zero point)± 0.2 % of full scale/10 K
Medium temperaturefrom -30 to 120 °C

Output

Output functionAnalog output current
Output 1Analog output

Other

Process connectionNPT 1/4 Außengewinde
Housing materialEdelstahl
Housing materialKunststoff
Analog output4…20 mA
Connector typeM12