HomeProcess SensorsFlow SensorsSL90F001
IPFSensor flow, air, calorimetric, 176x75x300mm, R 1/2", 18-36V DC, 4-20mA, M12 plug connector 5-pin, plastic PC, pressure resistance 16bar, with display, parameterization, RS-485, MBus – Image 1
IPF

Sensor flow, air, calorimetric, 176x75x300mm, R 1/2", 18-36V DC, 4-20mA, M12 plug connector 5-pin, plastic PC, pressure resistance 16bar, with display, parameterization, RS-485, MBus

SKU: SL90F001
Available3–5 business days delivery
€1,205.00 / pieces
€1,433.95 incl. VAT

These are our list prices.Get an individual quote within 24 h.

Request a quote
Data sheet(DE)

Features

  • The function of the flow sensor is based on the calorimetric principle. The sensor is heated by a few degrees Celsius from the inside compared to the flow medium into which it protrudes. If the medium flows, the heat generated in the sensor is dissipated by the medium. The temperature generated in the sensor is measured and compared with the temperature of the medium, which is also measured. The flow state for each medium can be derived from the temperature difference obtained. Applications for these sensors include compressed air consumption measuring devices.

Other features

Reference medium / objectAir
ApplicationPneumatik-Anwendungen

Electrical features

Design of the interface connectionPlug-in connection M12
Coding of the interface connectionA-coded
Elektrischer AnschlussConnector M12
Elektrischer AnschlussM12 5-pin plug connector
Setting procedureParameterization
Number of poles5
Type of analogy output4…20 mA
Measurement principlecalorimetric
Supported communication interfaceMBus | RS485
IndicationLCD display
No-load current120 mA
Protection functionsVerpolungsschutz | Kurzschlussschutz
Operating voltage (DC)18 - 36 V
Operating voltagefrom 18 to 36 V
Measurement accuracy± 1.5 % of measuring range ± 0.3 % of measuring range end

More

IPF Product Group725 compressed air and leakage measurement
packaging dimensions320 x 95 x 240 mm
Customs tariff number90268020
WEEE number40951076
Reach-compliantYes
RoHS‑compliantYes
gross weight994 g

Installation / Disposal

DisposalWEEE number according to § 6 para. 3 ElektroG: 40951076
InstallationMounting / installation may only be carried out by a qualified electrician!

Mechanical features

Measurement range flow velocity0,18 - 185 m/s
Height176.4 mm
Width300 mm
Pressure resistance16 bar
Ambient temperaturefrom -20 to 70 °C
Process connectionR1/2 inch
Length75 mm
Housing materialPlastic PC
Material of measuring transducerStainless steel 1.4301
Medium temperaturefrom -30 to 80 °C
DesignCuboid, integrated measuring section
Measurement range flow volume3,3 - 1500 l/min
Degree of protection (IP)IP65
Abmessung75x300x176,4mm

Other

Process connectionR1/2
Number of poles5-polig
DesignQuader
Connector typeM12

Safety warnings

  • Before initial operation, please make sure to follow all safety instructions that may be provided in the product information.
  • Never use these devices in applications where the safety of a person depends on their functionality.
  • Any software, drivers or IODD files that may be required to operate your device can be downloaded free of charge from our homepage: www.ipf-electronic.com