HomeProcess SensorsFlow Sensors100001008
Turck Flow Sensor – Image 1
Turck

Flow Sensor

SKU: 100001008 Type: FS100-300L-04-2UPN8-H1141
Available 3–5 business days delivery
€340.50 / pieces
€405.20 incl. VAT
Data sheet

Features

  • Screw-in adaptor with process connection G1/4" male thread included in delivery
  • Sensor housing material 1.4404 (316L)
  • Medium contact material 1.4571 (316Ti)
  • Immersion depth 16.9 mm
  • Process value display with bar graph
  • Flow monitoring for liquid media
  • Protection classes IP66, IP67 and IP69K
  • Adjustment of flow speed via teach function
  • 10…33 VDC
  • NO/NC contact, PNP/NPN output, IO-Link
  • Connector, M12 × 1

Functional principle

The flow sensor functions according to the calorimetric principle. The distinctive feature of this principle is that the flow rate correlates directly to the thermal loss of energy in the probe. The increased loss of energy is therefore a direct measure of an increased flow rate.

LED display

Flow Yellow On NO: Flow switchpoint exceeded (output "high")
Flow NC: Flow below minimum switchpoint (output "high")
Flow Off NO: Flow below minimum switchpoint (output "low")
Flow NC: Flow switchpoint exceeded (output "low")
Flow Flashing Teach mode/display of diagnostic data
Flow (see manual for specification)
Temp Yellow On NO: Temperature switchpoint exceeded (output "high")
Temp NC: Temperature below minimum switchpoint (output "high")
Temp Off NO: Temperature below minimum switchpoint (output "low")
Temp NC: Temperature switchpoint exceeded (output "low")
Temp Flashing Teach mode/display of diagnostic data
Temp (see manual for specification)
IO-Link proc ess data image
For detailed description of the display patterns and flashing codes, see manual D10000208
PWR Green On Operating voltage applied
PWR Device is operational
PWR Flashing Operating voltage applied
PWR IO-Link communication active
PWR (inverted flash with T on 900 ms and T off 100 ms)
LED Color Status Description

Flow Monitoring

Reproducibility +/- 1…30 cm/s; for water 3…300 cm/s
Reproducibility +/- 0.2…5 cm/s ; for water 3…100 cm/s;
Reproducibility +/- 10…80 °C
Switching point accuracy Directed inflow to punch mark ±20 °
Temperature drift 0.5 cm/s x 1/K
Standard flow range 3…300 cm/s
Standard flow range Any axial alignment of the sensor rod in
Standard flow range the medium
Hysteresis ≤ 300 K/min
Hysteresis 3 … 25 % of the switching point
Extended flow range 1…300 cm/s
Temperature gradient 0.5 cm/s × 1/K
Response time T09 6 s

Temperature monitoring

Reproducibility +/- ≤ 0.5 K
Reproducibility +/- 12 s
Switching point accuracy ± 2 K; for water >3 cm/s
Resolution 0.5 K
Measuring range -25…85 °C
Response time T09 3 s

Application range

Bar length (L1) 45 mm
Pressure resistance 300 bar
Application range liquids
Installation conditions Immersion sensor

Electrical data

Standby delay time 18…30 s
Short-Circuit/Reverse Polarity Protection yes, cyclic / yes (voltage supply)
Voltage drop ≤ 1.8 VDC
Overload protection Yes
Operating voltage UB from 10 to 33 VDC
Power consumption up to 1.6 VA
Electrical safety class III

Ambient Conditions

Vibration resistance 20 g (55…2000 Hz)
Ambient temperature from -40 to 80 °C
Storage temperature from -40 to 80 °C
Shock resistance 50 g (11 ms) DIN EN 60068-2-27

Tests/approvals

MTTF 120 years acc. to SN 29500 (Ed. 99) 40
MTTF °C
Indication LED display functions for status of supply
Indication voltage, switching states and teach processes. Process indicators via bar graph.
UL registration number E516036
Approvals cULus
Approvals CE

IO-Link

IO-Link port type Class A
Frame type 2.2
Included in the SIDI GSDML Yes
IO-Link specification V 1.1

Mechanical data

Elektrischer Anschluss Connector, M12 × 1
Adapter material Stainless steel 1.4571 (316Ti)
Process connection G 1/4'' male thread
Materials (media-contacting) Stainless steel 1.4571 (AISI 316Ti), FKMO-ring, AFM flat seal
Process connection adapter M18 × 1.5 male thread; G 1/4'' male
Process connection adapter thread
Housing material Stainless-steel/Plastic, 1.4404 (AISI
Housing material 316L)/Grilamid TR90 UV/Elastollan C 65
Housing material A 15 HPM 000/Ultramid A3X2G5
Electromagnetic compatibility (EMC) DIN EN 60947-5-9: 2007
Process connection sensor M18 x 1.5 female thread
Degree of protection (IP) IP67
Degree of protection (IP) IP66
Degree of protection (IP) IP69K

Output

Output function NO/NC programmable, PNP/NPN
Output 1 Flow: Switching output or IO-Link
Output 2 Temperature: Switching output
Communication protocol IO-Link

Allgemein

Medium temperature from -25 to 85 °C

Programming

Programming options Automatic switching logic recognition,
Programming options easy switching pointadjustment via touchpads