HomeProcess SensorsFlow Sensors100002693
TurckFCMI-15D12DYA4P-LIUP8X-H1141/S1352 Flow Rate Measurement – Inline Sensor with Integrated Processor – Image 1
Turck

FCMI-15D12DYA4P-LIUP8X-H1141/S1352 Flow Rate Measurement – Inline Sensor with Integrated Processor

SKU: 100002693 Type: FCMI-15D12DYA4P-LIUP8X-H1141/ S1352
Available3–5 business days delivery
€1,207.00 / pieces
€1,436.33 incl. VAT

These are our list prices.Get an individual quote within 24 h.

Request a quote
Data sheet

Features

  • Programmable flow meter for electrically conductive liquids
  • Magnetic-inductive principle
  • Display and monitoring of flow
  • 3-digit display [l/min]
  • Measuring accuracy 0…10l/min: <+/‐0.2 l/ min
  • Measuring accuracy 10…80l/min: <+/‐2% of minimum value
  • Minimum conductivity > 20 µS/cm (water > 30 µS/cm)
  • Prog. via pushbutton, code-protected
  • Device fully potted
  • DC 4-wire, 21.6…26.4 VDC
  • NO/NC prog., PNP output
  • 4…20 mA analog output
  • Analog output provides a current signal proportional to the flow rate for the overall operating range
  • Plug-in device, M12 x 1

Functional principle

The magnetic-inductive inline flow meter FCMI by TURCK is based on the Faraday principle. A measuring tube permeating magnetic field deviates the free charge carriers in the targeted medium to the tube walls. Voltage is created by electrical separation and picked up by two laterally mounted electrodes. The voltage quantity depends on the flow rate i.e.flow if the magnetic field is known. Thus the FCMI flow meter monitor reliably and wear-free the flow of various different liquid media which feature a determined minimum conductivity.

Electrical data

Load200…500 Ω
Current output4…20 mA
Electricity consumptionup to 100 mA
Short circuit protectionyes
Polarity protectionyes
Output functionPNP/Analog output, NO/NC programmable
Rated operating current0.2 A
Operating voltagefrom 21.6 to 26.4 V
Degree of protection (IP)IP65

Mechanical data

Sensor materialStainless-steel/Plastic, 1.4571 (AISI
Sensor material316Ti)/PVDF
Elektrischer AnschlussConnector, M12 × 1
Pressure resistance10 bar
Process connectionCompression fittings for pipes Ø 15 × 1.5
Process connection(EN10305-1)
DesignInline
Housing materialPlastic, PBT
Programming optionsaccess code, switch-point, N.C./N.O, hysteresis, switch-on/switch-off delay,signal
Programming optionsfilter

Allgemein

Switch-on time0.5…8 s
Ambient temperaturefrom 0 to 60 °C
Standby time6…10 s
Application rangeliquids
Special versionS1352 Corresponds to:Full potting - protection against moisture penetration
Medium temperaturefrom 5 to 60 °C
Installation conditionsInline sensor
Flow operating range0…80 l/min

Other

Process connectionRohrverschraubung
DesignInline
Housing materialKunststoff
Analog output4…20 mA
Connector typeM12
Switching outputSchließer/Öffner
Switching outputPNP