HomeSensor AnalyticsFieldbus Modules100004252
Turck Compact multiprotocol I/O module for Ethernet 16 Universal Digital Channels, Configurable as PNP Inputs or 2 A Outputs – Image 1
Turck

Compact multiprotocol I/O module for Ethernet 16 Universal Digital Channels, Configurable as PNP Inputs or 2 A Outputs

SKU: 100004252 Type: TBEN-LL-16DXP
Available 3–5 business days delivery
€375.40 / pieces
€446.73 incl. VAT
Data sheet

Features

  • PROFINET device, EtherNet/IP device, Modbus TCP server, CC-Link IE field basic
  • Integrated Ethernet switch
  • Supports 10 Mbps/100 Mbps
  • 2 × M12, 4-pin, D-coded, Ethernet fieldbus connection
  • PROFINET S2 system redundancy
  • Glass fiber reinforced housing
  • Shock and vibration tested
  • Fully potted module electronics
  • Protection classes IP65, IP67, IP69K
  • M12, 5-pin, L-coded male connector for power supply
  • Galvanically isolated voltage groups support passive safety
  • ATEX zone 2/22
  • CCC-Ex
  • Input diagnostics per port
  • Max. 2 A per output
  • Output diagnostics per channel
  • Two freely selectable digital channels per port
  • Programmable ARGEE

EtherNet/IP™

Class 3 connections (TCP) 3 TCP
Addressing acc. to EtherNet/IP specification
Configuration Assembly Instance 106
Quick Connect (QC) < 150 ms
Output Assembly Instance 102
Input Assembly Instance 101
min. RPI 2 ms
Class 1 connections (CIP) 10 CIP
Device Level Ring (DLR) supported

General Information

Mounting 2 mounting holes ￿ 6.3 mm
ERR Green On No diagnostics available
ERR Red On Diagnostics available
ERR Undervoltage diagnosis response is parameter-dependent
MTTF 134 years acc. to SN 29500 (Ed. 99) 20 °C
Halogen free yes
L/A Green On Ethernet link (100 Mbps)
L/A Flashing Ethernet communication (100 Mbps)
L/A Yellow On Ethernet link (10 Mbps)
L/A Flashing Ethernet communication (10 Mbps)
L/A Off No Ethernet link
Ambient temperature from -40 to 70 °C
Connector material Nickel-plated brass
Material screw 303 stainless steel
Dimensions (L x W x H) 60.4 x 230.4 x 34.8 mm
Housing colour Black
Storage temperature from -40 to 85 °C
PWR LED response parameter (PWR) at V undervoltage = "red"
PWR 2
PWR Green On V and V power supply OK
PWR 1 2
PWR Red On V power supply off or V undervoltage
PWR 2 2
PWR Off V power supply off or V undervoltage
PWR 1 1
PWR LED response parameter (PWR) at V undervoltage = "green"
PWR Flashing V power supply off or V undervoltage
Window material Lexan
Altitude Max. 5000 m
LED Color Status Description
Housing material PA6-GF30
Material label Polycarbonate
BUS Green On Active connection to a client
BUS Flashing Steady flashing: ready for operation
BUS Sequence of 3 flashes in 2 seconds: FLC/ARGEE active
BUS Red On IP address conflict or Restore mode or Modbus timeout
BUS Flashing Blink/Wink command active
BUS Green/red Alternating Autonegotiation and/or waiting for DHCP/Boot-P addressing
BUS Off Power off
Degree of protection (IP) IP67
Degree of protection (IP) IP69K
Degree of protection (IP) IP65

LED Status I/O

LED 0 … 15 Green On Input or output active
LED 0 … 15 Red On Output active with overload/short circuit
LED 0 … 15 Flashing Power overload at the corresponding port. Both port LEDs are flashing.
LED 0 … 15 Off Input or output inactive

Digital outputs

Output current per channel 2.0 A, short-circuit proof, max. 2.0 A per port
Output voltage 24 VDC from potential group
Output type PNP
Short circuit protection yes
Type of load EN 60947-5-1: DC-13
Type of output diagnostics Channel diagnostics
Output delay 1.3 ms
Output connectivity M12, 5-pin

Digital inputs

Switching threshold EN 61131-2 Typ 3, PNP
Number of channels 16
Input delay 2.5 ms
Low level signal current < 1.5 mA
Low-level signal voltage < 5 V
Electrical isolation Galvanically isolated to the fieldbus
Electrical isolation Voltage proof up 500 VDC
High level signal current > 2 mA
Input type PNP
Type of input diagnostics Group diagnostics
High level signal voltage > 11 V
Connectivity inputs M12, 5-pin

PROFINET

Version 2.35
Addressing DCP
Diagnostics acc. to PROFINET alarm handling
Network load class 3
Topology detection supported
Fast Start-Up (FSU) < 150 ms
MinCycleTime 1 ms
Automatic addressing supported
System redundancy S2
Media Redundancy Protocol (MRP) supported
Conformance class B (RT)

System data

ARGEE functionality Supported
Protocol detection automatic
BEEP functionality Supported
Transmission rate fieldbus 10/100 Mbps
Service interface Ethernet via XF1 or XF2
Connection technology fieldbus 2 × M12, 4-pin, D-coded

Modbus TCP

Addressing Static IP, DHCP
Number of TCP connections 8
Supported function codes FC1, FC2, FC3, FC4, FC6, FC15, FC16, FC23
Output register start address 2048 (0x0800 hex)
Input register start address 0 (0x0000 hex)

Supply

Sensor/actuator supply Ports X0-X3 powered by V1
Sensor/actuator supply short-circuit proof, 120 mA per port
Sensor/actuator supply Ports X4-X7 powered by V2
Power dissipation, typical ≤ 10 W
Admissible range 18…30 VDC Pass-through current XD1–XD2 max.
Admissible range 16 A per voltage group Device current max. 9 A per
Admissible range voltage group Total current V1 + V2 max. 11 A UL
Admissible range derating for > 55 °C: Total current max. 6 A per voltage group
Fault exclusion Yes, acc. to EN ISO 13849-2, appendix D.2
Electrical isolation galvanic isolation of the voltage groups V1 and V2,
Electrical isolation voltages up to 500 VAC
Operating current V1: max. 150 mA
Supply voltage 24 VDC
Connection technology power supply M12, L-coded

CC-Link

Acyclic SLMP communication Yes
Interfaces CC-Link IE Field Basic
IP change mechanism Yes
Message Transmission Yes
Max. occupied stations 1
Profile specification CSP+

Standard/Directive conformity

Shock test acc. to EN 60068-2-27
Approvals and certificates CEUKCAATEX zone 2/22
Approvals and certificates CCC-Ex
Approvals and certificates FCC statement,
Approvals and certificates UV resistant acc. to DIN EN ISO 4892-2A (2013)
Vibration test Acc. to EN 60068-2-6
Vibration test Acceleration up to 20 g
UL Certificate cULus LISTED 21 W2, Encl.Type 1 IND.CONT.EQ.
Drop and topple acc. to EN 60068-2-31/IEC 60068-2-32
Note on ATEX/IECEx The Quick Start Guide with information on use in Ex
Note on ATEX/IECEx areas must be observed.
Electromagnetic compatibility (EMC) Acc. to EN 61131-2

Power supply

Supply voltage 24 VDC