Features
- • CODESYS V3 PLC Runtime
- • CODESYS WebVisu license
- • CODESYS OPC UA server/client
- • IoT gateway for Turck Cloud
- • PROFINET controller/device
- • EtherNet/IP scanner/device
- • EtherCAT master
- • Modbus TCP master/slave
- • Modbus RTU master/slave
- • CANopen manager/device
- • SAE J1939 manager
- • Serial interfaces RS232/RS485
- • Ethernet 2 × M12, 4-pin, D-coded
- • Switched or dual MAC mode
- • 10 Mbps/100 Mbps
- • Glass fiber reinforced housing
- • Shock and vibration tested
- • Fully potted module electronics
- • Protection classes IP65, IP67, IP69K
- • ATEX zone 2/22
- • CCC-Ex
- • Eight universal digital I/O channels
- • Sensor supply max. 2 A per port
- • Input diagnostics per port
- • Max. 2 A per output
- • Output diagnostics per channel
Programming CODESYS V3
| Programming interface | Ethernet, USB |
| Output data | 8 kByte |
| Input data | 8 kByte |
| Number of POUs | 1024 |
| Released for CODESYS version | V 3.5.14.2 |
| Application tasks | 10 |
| Cycle time | < 1 ms for 1000 AWL commands (without I/O cycle) |
| Programming languages | IEC 61131-3 (IL, LD, FBD, SFC, ST) |
General Information
| Mounting | 2 mounting holes 6.3 mm |
| Mounting | USB 2.0 mini-B Jack |
| Mounting | USB Device Interface |
| Mounting | For use as a programming interface (alternative to Ethernet) |
| Mounting | USB cable (example): |
| Mounting | USB 2.0 CABLE 1.5M (ID number 6827388) |
| Mounting | USB 2.0 Extension A-male on A-female: |
| Mounting | USB 2.0 EXTENSION 5M (ID number 6827389) |
| Mounting | USB 2.0 EXTENSION ACTIVE 5M (ID number 6827390) |
| ERR | Green ON Diagnostics disabled |
| ERR | Red ON Diagnostics enabled |
| ERR | OFF V1 power off or below defined tolerance (18 V) |
| APPL | green / red ON/OFF/Flashing This LED is controlled user-defined from the CODESYS program |
| APPL | White Flashing Blink/Wink command active |
| MTTF | 80 years acc. to SN 29500 (Ed. 99) 20 °C |
| Halogen free | yes |
| Ambient temperature | from -40 to 70 °C |
| Connector material | Nickel-plated brass |
| Material screw | 303 stainless steel |
| Dimensions (L x W x H) | 60.4 x 230.4 x 39 mm |
| Housing colour | Black |
| ETH1/ETH2 | Green ON Ethernet link (100 Mbps) |
| ETH1/ETH2 | Flashing Ethernet communication (100 Mbps) |
| ETH1/ETH2 | Yellow ON Ethernet link (10 Mbps) |
| ETH1/ETH2 | Flashing Ethernet communication (10 Mbps) |
| ETH1/ETH2 | OFF No Ethernet link |
| Storage temperature | from -40 to 85 °C |
| PWR | Green ON V and V power on |
| PWR | 1 2 |
| PWR | Red ON V power off or below defined tolerance of 18 V |
| PWR | 2 |
| PWR | OFF V power off or below defined tolerance of 18 V |
| PWR | 1 |
| Window material | Lexan |
| Altitude | Max. 5000 m |
| LED | Color Status Description |
| Housing material | PA6-GF30 |
| Material label | Polycarbonate |
| RUN | Green ON SPS status running |
| RUN | Red ON SPS status stop |
| RUN | Flashing No PLC program loaded |
| RUN | Flashes 2x 1Hz Factory Reset executed |
| RUN | OFF V1 power off or below defined tolerance (18 V) |
| BUS | Green ON Active connection to the first configured master |
| BUS | Flashing Ready |
| BUS | Red ON IP-address conflict or Restore Mode or Modbus timeout |
| BUS | Flashing Blink/Wink command active |
| BUS | green / red alternating Autonegotiation and/or waiting for DHCP/Boot-P addressing |
| BUS | OFF V1 power off or below defined tolerance (18 V) |
| Degree of protection (IP) | IP67 |
| Degree of protection (IP) | IP69K |
| Degree of protection (IP) | IP65 |
Digital outputs
| Actuator power supply | 2 A, short-circuit proof, from V2 |
| Output current per channel | 2.0 A, short-circuit proof, max. 4.0 A per port |
| Output voltage | 24 VDC from V2 |
| Simultaneity factor | 0.56 |
| Output type | PNP |
| Short circuit protection | yes |
| Type of load | EN 60947-5-1: DC-13 |
| Type of output diagnostics | Channel diagnostics |
| Output connectivity | M12, 5-pin |
System data
| Web server | default: 192.168.1.254 |
| Connection technology Ethernet | 2 x M12, 4-pin, D-coded |
| Transmission rate Ethernet | 10/100 Mbps |
| Service interface | Ethernet via P1 or P2, Mini USB port |
Digital inputs
| Switching threshold | EN 61131-2 Typ 3, PNP |
| Number of channels | 8 |
| Sensor supply | 2 A, short-circuit proof, from V2 |
| Low level signal current | < 1.5 mA |
| Low-level signal voltage | < 5 V |
| Electrical isolation | Galvanically isolated to the fieldbus |
| Electrical isolation | Voltage proof up 500 VDC |
| High level signal current | > 2 mA |
| Input type | PNP |
| Type of input diagnostics | Channel diagnostics |
| High level signal voltage | > 11 V |
| Connectivity inputs | M12, 5-pin |
Operating mode RS232
| Transmission rate | 9600 to 230400 bps |
| Signal low level | -18 to -3 VDC |
| Signal high level | 3 to 18 VDC |
| Transmission signals | T×D, R×D |
| Transmission type | Full duplex |
| Cable length | 15 m at 19200 Bd |
| Cable length | (max. line capacitance < 2000 pF) |
Supply
| Sensor/actuator supply | Supply ports C0-C3 from V1 |
| Sensor/actuator supply | short-circuit proof, |
| Sensor/actuator supply | C0 + C1: 2 A per port, |
| Sensor/actuator supply | C2 + C3: 4 A for both ports |
| Sensor/actuator supply | Short-circuit proof supply of ports C4-C7 from V2, |
| Sensor/actuator supply | 2 A per port |
| Power dissipation, typical | ≤ 5 W |
| Admissible range | 18…30 VDC |
| Admissible range | Total current max. 9 A per voltage group |
| Admissible range | Total current V1 + V2 max. 11 A |
| Electrical isolation | galvanic isolation of the voltage groups V1 and V2, |
| Electrical isolation | voltages up to 500 VAC |
| Operating current | < 280 mA |
| Supply voltage | 24 VDC |
| Connection technology power supply | 7/8″, 4-pin |
Operating mode RS485
| Line impedance | 120 Ω |
| Transmission signals | TX/RX+, TX/RX- |
| Transmission type | 2-wire half duplex |
| Terminating resistor | Internal or external |
Serial interface
| Number of channels | 2 |
| Signal type | RS232 or RS485 |
LED Status I/O
| LED 0 | Green ON COM 0: TX data transmission |
| LED 0 | OFF COM 0: no TX data transmission |
| LED 2 | Green ON COM 1: TX data transmission |
| LED 2 | OFF COM 1: no TX data transmission |
| LED 1 | Green ON COM 0: RX data transmission |
| LED 1 | OFF COM 0: no RX data transmission |
| LED 3 | Green ON COM 1: RX data transmission |
| LED 3 | OFF COM 1: no RX data transmission |
| LED 4 … 7 | green / red ON/OFF/Flashing This LED is controlled user-defined from the CODESYS program |
| LED 8 … 15 | Green ON Input or output active |
| LED 8 … 15 | Red ON Output active with overload/short circuit |
| LED 8 … 15 | Flashing Power overload at the corresponding port. Both port LEDs are flashing. |
| LED 8 … 15 | OFF Input or output inactive |
Controller
| Remanent memory | 64 kB |
| Operating System | Linux |
| Processor | ARM Cortex A8, 32 Bit, 800 MHz |
| Real time clock | yes |
| Program memory and data memory | 20 MB |
| Add-on memory | 1 x USB host port |
Standard/Directive conformity
| Shock test | acc. to EN 60068-2-27 |
| Approvals and certificates | CEUKCAATEX zone 2/22 |
| Approvals and certificates | CCC-Ex |
| Approvals and certificates | FM class I, zone 2, |
| Approvals and certificates | UV resistant acc. to DIN EN ISO 4892-2A (2013) |
| Vibration test | Acc. to EN 60068-2-6 |
| Vibration test | Acceleration up to 20 g |
| UL Certificate | cULus LISTED 21 W2, Encl.type 1 IND.CONT.EQ. |
| Drop and topple | acc. to EN 60068-2-31/IEC 60068-2-32 |
| Note on ATEX/IECEx | The Quick Start Guide with information on use in Ex |
| Note on ATEX/IECEx | areas must be observed. |
| Electromagnetic compatibility (EMC) | Acc. to EN 61131-2 |
Power supply
| Supply voltage | 24 VDC |