HomeSensor AnalyticsIO-LinkVL310304
IPF Logic module, 27x88x31mm, AND/OR, 4-gang, 10-30V DC, sensor side M8 socket 3-pin, control side M12 connector 4-pin, IP67, plastic, IO-Link – Image 1
IPF

Logic module, 27x88x31mm, AND/OR, 4-gang, 10-30V DC, sensor side M8 socket 3-pin, control side M12 connector 4-pin, IP67, plastic, IO-Link

SKU: VL310304
Available 3–5 business days delivery
€143.00 / pieces
€170.17 incl. VAT
Data sheet (DE)

Features

  • IO-Link interface bounce protection by pulse stretching
  • Linking digital signals directly at the machine can contribute to a significant reduction in costs and effort. A classic application is the linking of different signals directly in the field. In this way, long cable runs of many individual devices can be avoided, this contributes to a significant minimization of the wiring effort and reduces the need for control inputs. All input signals on the logic modules are visualized by integrated LEDs and are electrically decoupled from each other. This reliably prevents influences from one device to the other. The outputs of the modules are overload-proof and the pending signal is also indicated via an LED. Along with logical input signal links such as AND or OR, versions with signal change control are also available. The ipf logic modules are available for DIN rail mounting or as field modules. Because of this and because of the robust housing, which is characterized by a high degree of protection against the ingress of dust and water, our devices can be used in all areas of machines, plants and tools.

More

IPF Product Group 800 miscellaneous
packaging dimensions 220 x 150 x 40 mm
POP-compliant Yes
Customs tariff number 85365005
WEEE number 40951076
Reach-compliant Yes
RoHS‑compliant Yes
gross weight 76 g

Installation / Disposal

Disposal WEEE number according to § 6 para. 3 ElektroG: 40951076
Installation Mounting / installation may only be carried out by a qualified electrician!

Classification

ETIM 8 EC001417 Logic module

Electrical features

Number of inputs per logic unit 4
Supported communication interface IO-Link
Number of logic units 2
Indication LED display
Logic AND/OR
Design of electrical connection A Connector M8
Design of electrical connection B Connector M12
Operating voltage (DC) 10 - 30 V
Number of poles connection A 3
Number of poles connection B 4
Rated switch current 100 mA

Mechanical features

Max. tightening torque connection A 0.6 Nm
Max. tightening torque connection B 1 Nm
Height 27.3 mm
Width 30.6 mm
Mounting method Screw mounting
Ambient temperature from -20 to 70 °C
Length 88.2 mm
Housing material Plastic
Degree of protection (IP) IP67

Other features

IO-Link version V1.1

Safety warnings

  • Before initial operation, please make sure to follow all safety instructions that may be provided in the product information.
  • Never use these devices in applications where the safety of a person depends on their functionality.
  • Any software, drivers or IODD files that may be required to operate your device can be downloaded free of charge from our homepage: www.ipf-electronic.com