Turck
Turck
Inline Converter Analog to IO-Link Converter
SKU: 100036698 Type: ILC-AIU-M12-IOL8X2-H1141
Available 3–5 business days delivery
€82.80 / pieces
€98.53 incl. VAT
Features
- • Direct connection to an analog sensor due to compact design
- • 300-mm cable ("L") with M12 × 1 female connector, 4-pin
- • M12 × 1 male connector, 4-pin
- • Operating voltage: 18…30 VDC
- • Protection class: IP67
- • Parameterizable via IO-Link
- • Input (300-mm cable with female connector, M12 × 1, 4-pin): adjustable; current 0… 20/4…20 mA and voltage 0…5/1…6/0… 10 V
- • Output (M12 × 1 male connector, 4-pin): IO-Link
- • For connecting analog sensors to an IOLink master
Functional principle
Sensors with analog outputs can be used to communicate via IO-Link to provide the data required for predictive maintenance and operational optimization. ension drawing
IO-Link
| Maximum Cable Length | 20 m |
| Communication mode | COM 3 (230.4 kBaud) |
| Function pin 4 | IO-Link |
| Frame type | Type_2_2 |
| Process data width | 32 bit |
| IO-Link specification | V 1.1 |
Mechanical data
| Elektrischer Anschluss | Connector, M12 × 1, 0.3 m |
| Ambient temperature | from -25 to 70 °C |
| Design | Cylinder, threaded, M12 |
| Housing material | Metal/plastic, CuZn |
| Degree of protection (IP) | IP67 |
| Abmessung | Ø 12 x 75 mm |
Electrical data
| Input type | 0/4…20 mA or -10/0…10 VDC |
| Communication protocol | IO-Link |
| Operating voltage UB | from 18 to 30 VDC |
Tests/approvals
| Approvals | cULus |
| Approvals | CE |