HomePosition SensorsTilt Sensors100030753
TurckInclinometer With Analog Outputs – Image 1
Turck

Inclinometer With Analog Outputs

SKU: 100030753 Type: B1N360V-QR20-2LI2X3-H1151
Available3–5 business days delivery
€195.00 / pieces
€232.05 incl. VAT

These are our list prices.Get an individual quote within 24 h.

Request a quote
Data sheet

Features

  • Rectangular, plastic, Ultem
  • Status displayed via LED
  • Angle detection via one axis with 360 ° measuring range
  • High protection class IP68/IP69K
  • Protected against salt spray and rapid temperature change
  • 15…30 VDC
  • M12 × 1 male connector, 5-pin
  • Two counter-running 4…20 mA analog outputs improve machine safety through redundancy
  • The start, end and center point of the measuring range can be adjusted using teach adaptor TX1-Q20L60
  • Individual parameterization possible with USB-2-IOL-0002

Functional principle

The inclinometers use an acceleration measuring cell to determine the angle. The Earth's gravity is used as a reference. If the inclinometer changes its angle relative to the Earth's gravity, this is detected by the acceleration measuring cell. The robust sensors are positioned with the cast side on a flat surface so that the casting compound is covered. The sensor is then secured with two screws.

Electrical data

Wire break/reverse polarity protectionyes/yes
Isolation test voltage0.5 kV
Load resistance voltage output≥ 4.7 kΩ
Current output4…20 mA
Electricity consumptionup to 80 mA
Short circuit protectionyes
Output function5-pin, Analog output
Load resistance current output≤ 0.4 kΩ
Ripple Uss≤ 10 % UBmax
Operating voltagefrom 15 to 30 V

Ambient Conditions

Display operating voltageLED, Green
Vibration resistance20 g; 5 h/Achse; 3 Achsen
MTTF297 years acc. to SN 29500 (Ed. 99) 40 °C
Ambient temperaturefrom -40 to 85 °C
Temperature changes (EN60068-2-14)-40… +85 °C; 20 cycles
Measuring range displayLED, yellow
UL CertificateE351232
Shock resistance150 g; 4 ms ½ sine
Degree of protection (IP)IP69K
Degree of protection (IP)IP68

General data

Number of measurement axes1
Temperature drift≤ ± 0.006 %/K
Resolution16 bit
Repeatability≤ 0.05 % of full scale
Measuring range0…360°
Linearity deviation≤ 0.2 %

Mechanical data

Elektrischer AnschlussConnector, M12 × 1
DesignRectangular, QR20
Housing materialPlastic, Ultem
Abmessung71.6 x 62.6 x 20 mm

Allgemein

Measurement principleAcceleration

Other

DesignQuader
Housing materialKunststoff
Analog output4…20 mA
Connector typeM12