| Mode 2 “Lower hemisphere” | Bridge Pin 1 (U) and Pin 8 twice briefly LED (green) flashes twice |
| Mode 2 “Lower hemisphere” | B |
| Measuring range end, Y-axis | Bridge Pin 3 (GND) and Pin 8 for 3 s Status LED (yellow) flashes, after 1 s steady, after 3 s |
| -85°…+85° | Bridge Pin 3 (GND) and Pin 8 four times LED (yellow) flashes four times |
| -85°…+85° | briefly |
| Mode 1 “Upper hemisphere,” | Bridge Pin 1 (U) and Pin 8 once briefly LED (green) flashes once |
| -60°…+60° | Bridge Pin 3 (GND) and Pin 8 three times LED (yellow) flashes three times |
| -60°…+60° | briefly |
| Parameter | Teach input LED |
| Transmission rate | COM 2 / 38.4 kbps |
| Vibration resistance | 55 Hz (1 mm) |
| 15 Hz | Bridge Pin 3 (GND) and Pin 8 twice briefly LED (yellow) flashes twice |
| MTTF | 159 years acc. to SN 29500 (Ed. 99) 40 °C |
| Mode 5, Y: 0…360°, X: off | Bridge Pin 1 (U) and Pin 8 five times briefly LED (green) flashes five times |
| Mode 5, Y: 0…360°, X: off | B |
| Pre-set mode Angle | Bridge Pin 1 (U) and Pin 8 for 10 s You mustStatus LED (green) flashes, after 10 s steady |
| Pre-set mode Angle | Bset a further teach input within 10 s or the |
| Pre-set mode Angle | device exits this mode automatically |
| Frame type | 2.2 |
| Zero point offset (see notes) | Bridge Pin 3 (GND) and Pin 8 for 5 s Status LED (yellow) flashes, after 1 s steady, after 3 s |
| Zero point offset (see notes) | flashes, after 5 s steady |
| Construction | rectangular, Q42 |
| Connection | male, M12 x 1 |
| Dimensions (L x W x H) | 67.5 x 42.5 x 42.5 mm |
| Mode 3, 2 x 360° | Bridge Pin 1 (U) and Pin 8 three times LED (green) flashes three times |
| Mode 3, 2 x 360° | B |
| Mode 3, 2 x 360° | briefly |
| Housing material | plastic, PA |
| Mode 4, X: 0…360°, Y: off | Bridge Pin 1 (U) and Pin 8 four times briefly LED (green) flashes four times |
| Mode 4, X: 0…360°, Y: off | B |
| Filter setting mode | Bridge Pin 3 (GND) and Pin 8 for 10 s You Status LED (yellow) steady, after 10 s flashes |
| Filter setting mode | must set a further teach input within 10 s or |
| Filter setting mode | the device exits this mode automatically |
| Pre-set mode Function | Bridge Pin 1 (U) and Pin 8 for 10 s You mustStatus LED (green) steady, after 10 s flashes |
| Pre-set mode Function | Bset a further teach input within 10 s or the |
| Pre-set mode Function | device exits this mode automatically |
| -45°…+45° | Bridge Pin 3 (GND) and Pin 8 twice briefly LED (yellow) flashes twice |
| 24 Hz, default setting | Bridge Pin 3 (GND) and Pin 8 once briefly LED (yellow) flashes once |
| Factory setting | B |
| Factory setting | Bridge Pin 3 (GND) or Pin 1 (UB) and Pin 8 LED flashes fast after 15 s |
| Factory setting | for 15 s |
| Measuring range end, X-axis (see notes) | Bridge Pin 1 (U) and Pin 8 for 3 s Status LED (green) flashes, after 1 s steady, after 3 s |
| Measuring range end, X-axis (see notes) | B |
| Measuring range end, X-axis (see notes) | flashes |
| Shock resistance | 30 g (11 ms) |
| Most effective filter setting | Bridge Pin 3 (GND) and Pin 8 three times LED (yellow) flashes three times |
| Most effective filter setting | briefly |
| IP Rating | IP68 / IP69K |
| Measuring range start, X-axis | Bridge Pin 1 (U) and Pin 8 for 1 s Status LED (green) flashes, after 1 s steady |
| -10° … +10° | Bridge Pin 3 (GND) and Pin 8 once briefly LED (yellow) flashes once |