Features
- • Integrated web server with reader parameterization
- • Web-based UHF RFID test tool for easy air interface evaluation
- • Resistant to UV radiation
- • 4 connections for passive UHF RFID antennas
- • 4 configurable digital channels as PNP inputs and/or outputs with 0.5 A per channel
- • Programmable according to IEC 61131-3 with CODESYS V3
- • Codesys V3 PLC Runtime
- • CODESYS OPC-UA server
- • PROFINET device, EtherNet/IP device or Modbus TCP master/slave
- • "U" data interface for convenient use of the RFID functionality
- • Close-to-control integration in PLC systems without the use of a special function module
- • LEDs and diagnostics
- • Device only suitable for operation in Brazil (BRA) at 915…928 MHz
Functional principle
The UHF readers form a transmission zone, the size of which may vary depending on the combination of reader and tag used. The achievable distances may be different due to component tolerances, mounting location in the application, ambient conditions and the effect of materials (particularly metal). Testing of the application under real operating conditions is therefore essential, especially with on-the-fly reading and writing!
Programming CODESYS V3
| Programming interface | Ethernet |
| Output data | 8 |
| Input data | 8 |
| Number of POUs | 1024 |
| Released for CODESYS version | V 3.5.11.20 |
| Application tasks | 10 |
| Cycle time | < 1 ms for 1000 IL commands (without I/ |
| Cycle time | O cycle) |
| RFID data interface | UHF |
| Programming languages | IEC 61131-3 (IL, LD, FBD, SFC, ST) |
EtherNet/IP™
| Class 3 connections (TCP) | 3 TCP |
| Addressing | acc. to EtherNet/IP specification |
| Input Data Size | 248 |
| Configuration Assembly Instance | 106 |
| Output Assembly Instance | 104 |
| Input Assembly Instance | 103 |
| Class 1 connections (CIP) | 10 CIP |
| Output Data Size | 248 |
| Device Level Ring (DLR) | supported |
Electrical data
| DC rated operational current | ≤ 3500 mA |
| Output power | 500 kHz |
| Output power | ≤ 36 dBm (EIRP), adjustable |
| Data transfer | Alternating electromagnetic field |
| Radio and protocol standards | ISO 18000-63 |
| Technology | UHF RFID |
| Antenna polarization | circular/linear, adjustable |
| Output function | 65° |
| Output function | Read/Write |
| PoE standard | IEEE 802.3at (PoE+) |
| dards | EPCglobal Gen 2 |
| Operating region (UHF) | Brazil (902…907.5 + 915…928 MHz) |
| Operating voltage | from 18 to 30 V |
System description
| Memory | 256 MB Flash |
| RAM memory | 512 MB DDR3 |
| Processor | ARM Cortex A8, 32 Bit, 800 MHz |
Mechanical data
| Active area material | Glass fiber-reinforced polyamide, PA6GF30, black |
| Vibration resistance | 55 Hz (1 mm) |
| MTTF | 49 years acc. to SN 29500 (Ed. 99) 20 |
| MTTF | °C |
| Elektrischer Anschluss | RP-TNC |
| Input impedance | 50 Ohm |
| Ambient temperature | from -20 to 50 °C |
| Design | Rectangular |
| Installation conditions | Non-flush |
| Housing material | Aluminium, AL, Silver |
| Shock resistance | 30 g (11 ms) |
| Degree of protection (IP) | IP67 |
| Abmessung | 300 x 300 x 61.7 mm |
System data
| Web server | Default: 192.168.1.254 |
| Connection technology Ethernet | 1 x M12, 4-pin, D-coded |
| Transmission rate Ethernet | 10/100 Mbps |
Digital inputs
| Switching threshold | EN 61131-2 type 3, PNP |
| Number of channels | 4 |
| Low level signal current | < 1.5 mA |
| Low-level signal voltage | < 5 V |
| High level signal current | > 2 mA |
| Input type | PNP |
| Type of input diagnostics | Channel diagnostics |
| High level signal voltage | > 11 V |
| Connectivity inputs | M12, 5-pin |
Modbus TCP
| Addressing | Static IP, BOOTP, DHCP |
| Number of TCP connections | 8 |
| Input Data Size | max. 2014 |
| Supported function codes | FC1, FC2, FC3, FC4, FC5, FC6, FC15, |
| Supported function codes | FC16, FC23 |
| Output Data Size | max. 1024 |
PROFINET
| Addressing | DCP |
| Diagnostics | acc. to PROFINET alarm handling |
| Input Data Size | max. 512 |
| MinCycleTime | 4 ms |
| Automatic addressing | supported |
| Output Data Size | max. 512 |
| Media Redundancy Protocol (MRP) | supported |
General Information
| Packaging unit | 1 |
Digital outputs
| Output type | PNP |
| Type of output diagnostics | Channel diagnostics |
| Output connectivity | M12, 5-pin |
-
Accessories – Coaxial Cable for Passive UHF Antennas100028191 -
Accessories – Coaxial Cable for Passive UHF Antennas100028192 - HF240 coaxial cable, length 4 m100028193
-
Accessories – Coaxial Cable for Passive UHF Antennas100028194 - HF240 coaxial cable, length 8 m100028195
-
Accessories – Coaxial Cable for Passive UHF Antennas100028196 -
Accessories – Coaxial Cable for Passive UHF Antennas100028197
-
Accessories – External Passive UHF Antenna100028596 - Passive UHF RFID antenna with integrated VESA100 pins and dimensions of 280 × 280 mm100028602
-
Accessories – External Passive UHF Antenna100028600