Turck
Turck
Vibration & Temperature Sensor For Condition Monitoring with IO-Link
SKU: 100016543 Type: CMVT-QR20-IOLX3-H1141
Available 3–5 business days delivery
€195.00 / pieces
€232.05 incl. VAT
Features
- • Rectangular, plastic, Ultem
- • Status displayed via LED
- • Acceleration and speed output RMS or peak to peak of the vibration
- • Acceleration measuring range 16 g
- • Detection over 3 axes
- • Temperature measuring range -40 °C to +85 °C
- • High protection class IP68/IP69K
- • 18…30 VDC, communication via IO-Link
- • 10…30 VDC, SIO mode PNP/NPN switching outputs
- • M12 × 1 male connector, 4-pin
Functional principle
Condition monitoring sensors help to prevent unplanned downtimes and malfunctions during the production process. They monitor the condition of the machine as a preventative measure. Using the CM sensors can prevent system downtime or machine damage, which in turn improves system effectiveness and allows uninterrupted operation. The use of CMVT sensors also directly benefits the user in a quantifiable way. Information on vibration and temperature is output via the standardized IO-Link protocol. Warning and alarm messages are also displayed via simple switching outputs.
Ambient Conditions
| Display switch state | 2 × LEDs, Yellow |
| Display operating voltage | LED, Green |
| MTTF | 548 years acc. to SN 29500 (Ed. 99) 40 °C |
| Ambient temperature | from -40 to 85 °C |
| Temperature changes (EN60068-2-14) | -40… +85 °C; 20 cycles |
| UL Certificate | E351232 |
| Vibration resistance | 20 g; 5 h/Achse; 3 |
| Shock resistance | 200 g; 4 ms ½ sine |
| Degree of protection (IP) | IP69K |
| Degree of protection (IP) | IP68 |
Electrical data
| Isolation test voltage | 0.5 kV |
| Electricity consumption | up to 50 mA |
| Communication protocol | IO-Link |
| Ripple Uss | ≤ 10 % UBmax |
| Operating voltage UB | from 18 to 30 VDC |
IO-Link
| Communication mode | COM 3 (230.4 kBaud) |
| Function pin 4 | IO-Link/SIO |
| Function Pin 2 | SIO |
Mechanical data
| Elektrischer Anschluss | Connector, M12 × 1 |
| Design | Rectangular, QR20 |
| Housing material | Plastic, Ultem |
| Abmessung | 71.6 x 62.6 x 20 mm |
Temperatur (-)
| Measurement range temperature | -40…85 °C |
| Temperature linearity deviation | ≤ 1 % |
| Temperature repeatability | ≤ ± 2.4 % |
Vibration — Acceleration
| RMS measuring range | 16 g |
| RMS linearity deviation, typical | ≤ ±3 % @ 78 Hz |
| RMS resolution | 0.01 g |
| RMS repeatability, typical | ≤ ±5 % @ 78 Hz |
Vibration speed
| RMS measuring range | 0...320 mm/s @ 78 Hz |
| RMS linearity deviation, typical | ≤ ±1 % @ 78 Hz |
| RMS resolution | 0.01 mm/s |