HomeProcess SensorsTemperature Sensors100004227
Turck Temperature Detection – With Current Output – Image 1
Turck

Temperature Detection – With Current Output

SKU: 100004227 Type: TTMS-206A-CF-LI6-H1140-L100-50/150
Available 3–5 business days delivery
€120.50 / pieces
€143.39 incl. VAT
Data sheet

Features

  • Miniature design
  • Analog output 4…20 mA
  • Factory setting -50 °C…150 °C
  • Compression fitting process connection
  • Bendable probe (min. bending radius: 3x outer diameter; excluding 30-mm probe tip)

Functional principle

Temperatures are recorded over a mineral insulated transmitter and converted into a wide range of electrical output signals. The devices of the TTM miniature series are enclosed in a fully potted plastic housing and depending on the variant, they have either an IO-link output, power output and/or switching output.

Analog output

Load ≤ 0.86 kΩ at 24 VDC [R =(V –
Load Load supply
Load 5 V)/22 mA]
Current output 4…20 mA
Accuracy ± 0.2 K

Reference conditions acc. to IEC 61298-1

Auxiliary power 24 VDC
Humidity from 45 to 75 %
Atmospheric pressure from 860 to 1060 hPa
Temperatur (-) 15…+25 °C

Power supply

Short-Circuit/Reverse Polarity Protection yes / yes
Electricity consumption up to 20 mA
Operating voltage UB from 5 to 32 VDC
Degree of protection (IP) IP67
Electrical safety class III

Temperature behaviour

Temperature coefficient zero point TK0 ± 0.1 % of full scale/10 K
Temperature coefficient range TKs ± 0.1 % of full scale/10 K

Tests/approvals

MTTF 162 years acc. to SN 29500 (Ed. 99) 40
MTTF °C

Mechanical data

Sensor material Stainless steel, 1.4404 (AISI 316L)
Elektrischer Anschluss Connector, M12 × 1
Pressure resistance 100 bar
Process connection For compression fittings, thermowell or
Process connection direct mounting
Housing material Stainless steel, 1.4404 (AISI 316L)

Temperature range

Outer diameter 6 mm
Immersion depth L 100 mm
Note Max. temperature of electronics:
Note 80 °C/176 °F
Factory setting -50…150 °C
Factory setting -58…302 °F
Measuring range -50…150 °C
Measuring range -58…302 °F
Messelement (nach DIN IEC 751) Pt1000, DIN EN 60751, class A
Ansprechzeit (bei ruhender Luft) t₀₅ = 1.5 s / t₀₉ = 6.0 s in water @ 0.2 m/s

Ambient Conditions

Ambient temperature from -40 to 80 °C
Storage temperature from -40 to 80 °C

Output

Output function Analog output
Output 1 Analog output