Features

  • Advantages of our M12 power connectors:
  • Our M12 power connectors are ideal for supplying power to your industrial applications and are specially optimised for
  • harsh environments.
  • The L-coded connectors are available in 4- and 5-pin versions and offer a current carrying capacity of 16A per pin at 63V
  • DC. They are ideal for supplying power to decentralised devices such as I/O & fieldbus modules, power supply units,
  • fuses, engines and motors. The Profinet User Organisation (PNO) has also described the L-coding as the future
  • standard for the low-voltage supply of automation components, which ensures compatibility across different systems.
  • All Murrelektronik connectors are 100% tested during the manufacturing process to ensure the highest quality and
  • reliability. The contacts are gold-plated, which ensures excellent conductivity. Thanks to the high IP67 protection rating
  • and the integrated protective conduit connection, they are ideal for demanding industrial environments. They are also
  • vibration-resistant - this is guaranteed by the integrated vibration protection.
  • The M12 power connectors are designed in accordance with the IEC 61076-2-111 standard and UL-approved in
  • accordance with 2237 (PVVA - E492831). Our connectors are resistant to oils and cooling lubricants. However,
  • resistance to aggressive media should be tested for each specific application.
  • Different cable lengths are possible on request. Are you missing technical information? Feel free to use our technical
  • dictionary, where you will find explanations of coding and other technical details.
  • Product details:
  • Power
  • Male straight – female straight
  • M12 – M12, 4-pole
  • L-coded
  • with cable sleeves
  • Plastic housings with good resistance against chemicals and oils.
  • The resistance to aggressive media should be individually tested for your application. Further details on request.
  • Further cable lengths on request.

Installation | Cable

Travel speed 3.3 m/s @ 25 °C
Material property (jacket) abrasion-resistant, low adhesion, good machinability, matte
Freedom from ingredients (jacket) lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Voltage Withstand 10 kV @ 60 s
Withstand voltage (wire - wire) 10 kV @ 60 s
Torsional stress ± 180 °/m
Outer diameter insulation 2,85 mm
Shore hardness jacket 90 ± 5 Shore A
Function cable Power
Tolerance outer diameter (sheath) ± 5 %
Stranding 1 × 4 wires stranded
Conductor type (wire) strand class 6
Outer-diameter (jacket) 8.7 mm
Torsion speed 35 cycles/min
Bending radius (flexible) 5 × Outer diamete
Cable type 3
Amount strands (wire) 135 wire
Shore hardness wire insulation 60 ± 5 Shore D
Traversing distance (C-track) 5 m @ 25 °C
Material jacket PUR
Conductor resistance (wire) 7.98 Ω/km @ 20 °C
Material conductor wire Stranded copper wire, bare
Ingredient freeness wire insulation lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Conductor crosssection (wire) 2.5 mm²
Current load capacity (standard) to DIN VDE 0298-4
Cable identification P37
Diameter of single wires 0,15 mm
Diameter of single wires white (isolation blue), white (isolation brown), white (isolation black), black (white isolation)
Min. operating temperature (static) -50 °C
Nominal voltage max. 1.000 V
Acceleration (max.) 5 m/s² @ 25 °C
Cable weigth 137,75 g/m
Material wire insulation PP
Other resistances good resistance to gasoline, resistant to hydrolysis, resistant to microbes
Max. operating temperature (fixed) 80 °C / 90 °C @ 10
Chemical resistance good
No. of bending cycles (C-track) 5 Mio. @ 25 °C
Amount wires 4
No. of torsion cycles 5 Mio.
Flame resistance IEC 60332-1-2, IEC 60332-2-2, UL 1581 § 1080, CSA FT2
Wire arrangement black 4, blue 3, white 2, brown 1
Oil resistance IEC 60811-404
Operating temperature max. 80 °C / 90 °C @ 10000 h Operation
Operating temperature min. -25 °C
Current load capacity max. (wire) up to 20.8 A

Conformity

Product Standard EN IEC 61076-2-111

Mechanical data | Material data

Seal FKM
Housing PUR
Coating of fitting nickel plated
Screw connection Brass

Electrical data | Supply

Operating voltage DC max. 63 V
Current operating per contact max. 16 A

Device protection | Electrical

Additional condition protection degree inserted, screwed
Rated surge voltage 1.5 kV
Degree of protection (EN IEC 60529) IP67, IP65, IP69K
Material group (IEC 60664-1) I
Pollution degree 3

Mechanical data | Mounting data

Type of fastening inserted, screwed, Shaking protection

Diagnostics

Status indication LED No

Installation | Connection

Wrench width SW17

Environmental characteristics | Climatic

Additional condition temperature range depending on cable quality
Operating temperature max. 85 °C
Operating temperature min. -30 °C