Turck
Turck
Flow Monitoring – Immersion Sensor without Integrated Processor
SKU: 6870432 Type: FCS-GL1/2A4-NAEX-H1141
Available 3–5 business days delivery
€376.10 / pieces
€447.56 incl. VAT
Features
- • Ex sensor for liquid media
- • Calorimetric functionality
- • Adjustment via Ex signal processor
- • Status displayed via signal processor
- • Intrinsically safe Ex ib IIC T6…T3, for use in Zone 1
- • Connector device
- • 4-wire connection to an Ex signal processor
- • ATEX category II 2 G, Ex zone 1
- • ATEX category II 2 D, Ex zone 21
Functional principle
Our insertion - flow sensors operate on the principle of thermodynamics. The measuring probe is heated by several °C as against the flow medium. When fluid moves along the probe, the heat generated in the probe is dissipated. The resulting temperature is measured and compared to the medium temperature. The flow status of every medium can be derived from the evaluated temperature difference. Thus TURCK's wearfree flow sensors reliably monitor the flow of gaseous and liquid media.
Allgemein
| Water Operating Range | 1…100 cm/s |
| Oil Operating Range | 3…200 cm/s |
| Minimum immersion depth | ≥ 15 mm |
| Temperature jump, response time | max. 12 s |
| Switch-off time | typ. 2 s (1…13 s) |
| Switch-on time | typ. 2 s (1…13 s) |
| Standby time | typ. 8 s (2…18 s) |
| Medium temperature | from -20 to 85 °C |
| Installation conditions | Immersion sensor |
| Temperature gradient | ≤ 250 K/min |
Electrical data
| Device designation | EX II 2 G Ex ib IIC T6…T3 Gb |
| Device designation | EX II 2 D Ex ib IIIC T125 °C Db |
| Ignition protection category | Gas Ex ib IIC; dust Ex ib IIIC |
| Ex approval acc. to conformity certificate | TÜV 99 ATEX 1518 |
| Important note | For Ex applications, the values specified in the corresponding Ex certificates |
| Important note | (ATEX, IECEx, UL, etc.) apply. |
| Power | up to 0.69 W |
| Degree of protection (IP) | IP67 |
Mechanical data
| Sensor material | Stainless steel, 1.4571 (AISI 316Ti) |
| Elektrischer Anschluss | Connector, M12 × 1 |
| Pressure resistance | 60 bar |
| Included in delivery | 2 × AFM 34 G1/2 flat seal |
| Process connection | G 1/2" long version |
| Design | Immersion |
| Max. tightening torque of housing nut | 30 Nm |
| Housing material | Stainless steel, 1.4571 (AISI 316Ti) |
Tests/approvals
| Approvals | ATEX |
| Approvals | CE |
| Approvals | UKCA |
| Approvals | GOST |
-
Processor Unit – For the Connection of FCS/FCI Product Series Ex Flow Sensors (NAEX) IO-Link Device with Transistor Switching Outputs7525101 -
Processor Unit – For the Connection of FCS/FCI Product Series Ex Flow Sensors (NAEX) IO-Link Device with Relay Switching Outputs7525103 -
Processor Unit – For the Connection of FCS/FCI Product Series Ex Flow Sensors (NAEX) HART Device with Current and Transistor Outputs7525105