Processor Unit – For the Connection of FCS/FCI Product Series Ex Flow Sensors (NAEX) IO-Link Device with Transistor Switching Outputs

SKU: 7525101 Type: FMX-IM-3UP63X
Available3–5 business days delivery
€531.00 / pieces
€631.89 incl. VAT

These are our list prices.Get an individual quote within 24 h.

Request a quote
Data sheet

Features

  • For Ex ia resp. Ex ib sensors
  • Transistor outputs for flow, temperature and faults
  • Adjustment of switchpoint, no teaching of flow boundaries (QuickTeach)
  • LED band for indication of flow speed and media temperature
  • Monitoring of operating and display range
  • Detection of wire-break and short-circuit on the sensor side
  • Standard IO or IO-Link operating mode
  • Parametrized via pushbutton or software-supported via IO-Link
  • Associated equipment [Ex ia Ga/Da]
  • Connection of flow probes Zone 0/20

Functional principle

All Ex flow sensors from the FCS series (immersion sensors) and FCI series (inline sensors) can be operated with the FMX-IM external processing unit. The flow module features four status LEDs as well as a 10-segment LED band for local monitoring. Software-based diagnostic options are also available to the user, such as wirebreak and short-circuit on the sensor side. Furthermore, monitoring of flow rates and media temperatures within a predefined operating and display range. The upper and lower limits of the flow range are taught in using the max./min. teach mode implemented. The flow switchpoint is easily adjusted by means of the Quick-Teach function, without having to program a lower and upper limit of the flow range. Working on the calorimetric principle, the connectible sensors not only detect the flow rate but also the media temperature. The flow module can be operated either in IO-Link (IOL) or in standard IO (SIO) mode via the integrated IO-Link interface. In SIO mode, the switching outputs are operated in the standard way. In IOL mode the current process signal is transmitted cyclically as a 10 bit-serial value. Parametrization is initiated either via pushbutton or software-supported via IOLink interface. The actual parametrization is then implemented via the tool-based DTM or IODD within the FDT frame PACTware™ or acyclically near the control via On-Request Data Objects (ORDO).

Mechanical data

Flowyellow off Switching output flow [low]
Flowon Switching output flow [high]
Flowflashing Teach mode / display of diagnostic data
Flowfor specification see manual
FlowValue 10 Bit (Bit 15 = MSB, Bit 6 = LSB) not assigned Out 3 Out 2 Out1
Flow(Fault) (Temp) (Flow)
Tempyellow off Switching output media temperature [low]
Tempon Switching output media temperature [high]
Tempflashing Teach mode / display of diagnostic data
Tempfor specification see manual
MTBF101 Years
Mounting methodDIN rail mounting and mounting panel
Bit 1514 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Ambient temperaturefrom -25 to 70 °C
DesignSignal processor
PWRgreen on Operating voltage applied
PWRDevice ready for operation
PWRflashing Operating voltage applied
PWRIO-Link communication active
PWR(inverted flash with T on 900 ms and T off 100 ms)
LED display
LEDColor Status Description
Housing materialPlastic, Polycarbonate/ABS
FaultRed Off Switching output fault [high]
FaultOn Switching output flow [low]
Fault(for error pattern in combination with LEDs see manual)
For detaile IM/FMX-IM IO-Link (Prd description of the display patterns and flashing codes see instructi
For detaile IM/FMX-IM IO-Link (Process Data Objects)
Degree of protection (IP)IP20
Abmessung89 x 110 x 27 mm

IO-Link

Transmission rate38.4 kBit/s (COM 2)
Transmission physicsTransmission physics 3-wire physics
Transmission physics(PHY 2)
Communication modesTool based engineering via FDT / DTM,
Communication modesIODD. Acyclic communication via On-Request Data Objects
Included in the SIDI GSDMLYes
Communication channelClamp 12 and via front panel jack COM
Communication channel(PC)
IO-Link specificationV 1.0

Customizable output functions

Error monitoringtransistor output
Switching stateactive high / active low parametrizable
Switching state(transistor output error monitoring only
Switching stateactive low)
Flow Monitoringtransistor output
Electrical connections5-pole removable reverse polarity protected terminal blocks
Type of fasteningscrew connection
Temperature monitoringtransistor output
Switching current100 mA
Terminal cross-section≥ 1.5…≤ 2.5 mm²
Switching characteristicPNP
Switching voltagefrom 20 to 30 V

Tests/approvals

Device designationEx II (1) G [Ex ia Ga] IIC resp. II (1) D [Ex
Device designationia Da] IIIC
Relative humidityEN 60068-2-38
Declaration of conformity EN ISO/IEC5108M
EC type examination certificateTÜV 11 ATEX 078981
ApprovalsCE
ApprovalsC-UL U.S. submitted
IECEx certificate of conformityIECEx TUN 11.0005
Electromagnetic compatibility (EMC)Acc. to NE21

Electrical data

Measurement frequency5 Hz (every 200 ms with software filter)
Sensor current limitationapprox. 110 mA
Repeatability media temperaturetypical ± 1 K
Medium temperature[°C] with the SET button temporarily
Medium temperaturepressed
Measuring accuracy media temperaturetypical ± 7 K
Sensor current≤ 70 mA
Sensor voltage≤ 7 VDC
No-load current I0≤ 63 mA
Teach modesQuickTeach; min/max adjustment. Teach
Teach modesmodes incl. DeltaFlow monitoring (teach
Teach modesmodes are automatically released with
Teach modesthe change of flow speed).
Input functionConnection of flow sensors (Ex sensors
Input functionof the FCS/FCI product series only!)
Flow speed[%] after min/max adjustment (permanent)
Flow speed% after Quick-Teach (permanent)
Switchpoint hysteresis media temperature2 K
Operating voltagefrom 20 to 30 V
Repeatability flow ratetypical ± 1 % (of full scale)
Power consumptionup to 12.6 VA

Output functions

Switching current100 mA
Switching voltagefrom 20 to 30 V

Other

Housing materialKunststoff