HomeSensor AnalyticsFieldbus Modules100000041
TurckCODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP with WebVisu License – Image 1
Turck

CODESYS 3 Programmable Gateway for the BL67 I/O System Multiprotocol Ethernet Gateway for PROFINET, EtherNet/IP and Modbus TCP with WebVisu License

SKU: 100000041 Type: BL67-PG-EN-V3-WV
Available3–5 business days delivery
€679.00 / pieces
€808.01 incl. VAT

These are our list prices.Get an individual quote within 24 h.

Request a quote
Data sheet

Features

  • CODESYS V3 PLC Runtime
  • CODESYS WebVisu license
  • CODESYS OPC UA server/client
  • IIoT gateway for Turck Cloud
  • PROFINET device
  • EtherNet/IP device
  • Modbus TCP master/slave
  • Protection class IP67
  • LEDs for display of PLC status, supply voltage, group and bus faults
  • 2 × M12 Ethernet, 4-pin, D-coded
  • Switched or dual MAC mode
  • 10 Mbps/100 Mbps
  • 7/8″ male connector for power supply, 5pin

Functional principle

The programmable BL67 gateways can be used as autonomous PLCs or as decentral PLCs in a network interconnection for fast preprocessing of signals. BL67 gateways are the head component of a BL67 station. The BL67 extension modules communicate via the internal module bus with the gateway and can be configured independently of the fieldbus protocol.

Programming CODESYS V3

Programming interfaceEthernet, USB
Web server192.168.1.254 (Default)
Output data4 kByte
Non-volatile memory16 kByte
Storage512 kByte
Input data4 kByte
Released for CODESYS versionV 3.5.14.2
Application tasks5
Program memory1024 kByte
Cycle time< 1 ms for 1000 IL commands (without I/O cycle)
ProcessorARM, 32 Bit
Programming languagesIEC 61131-3 (IL, LD, FBD, SFC, ST)
Real time clockyes
Service interfaceEthernet, mini USB

Temperature derating

DIN rail mountingyes, Attention: Offset
> 55 °C Steady ambient airDerating: Max. power consumption = 5 A
MTTF116 years acc. to SN 29500 (Ed. 99) 20 °C
Relative humidity15…95 % (internal), level RH-2, no condensation
Relative humidity(when stored at 45 °C)
- up to 5 g (at 10 to 150 Hz)for mounting on DIN rail no drilling according to EN
- up to 5 g (at 10 to 150 Hz)60715, with end bracket
Included in delivery1 x end plate BL67
Direct mountingTwo mounting holes, Ø 6 mm
Shock testAcc. to IEC 60068-2-27
Type codeIdent no. Dimension drawing
Vibration testAcc. to EN 61131
Drop and toppleacc. to IEC 68-2-31 and free fall to IEC 68-2-32
Storage temperaturefrom -40 to 85 °C
> 55 °C Circulating air (Ventilation)Derating: Max. power consumption = 5 A
- up to 20 g (at 10 up to 150 Hz)for mounting on base plate or machinery Therefore
- up to 20 g (at 10 up to 150 Hz)every second module has to be mounted with two
- up to 20 g (at 10 up to 150 Hz)screws each.
Electromagnetic compatibility (EMC)Acc. to EN 61131-2
Degree of protection (IP)IP67

Allgemein

Nominal current from module bus≤ 100 mA
Field supply24 VDC
Admissible range18…30 VDC
System power supply24 VDC/5 VDC
Fieldbus addressingRotary switch, PGM, DHCP
Max. system supply current1.2 A
Max. field supply current10 A
max. load current Io10 A
Transmission rate fieldbus10/100 Mbps, Full/Half Duplex, Auto Negotiation,
Transmission rate fieldbusAuto Crossing
Max. sensor supply I sens4 A Short circuit fuse
Supply voltage24 VDC
Connection technology fieldbus2 × M12, 4-pin, D-coded
Connection technology power supply7/8″, 5-pin

Modbus TCP

AddressingStatic IP, DHCP
Input Data Sizemax. 1024 register
Supported function codesFC1, FC2, FC3, FC4, FC5, FC6, FC15, FC16, FC23
Output register start address0 (0x0000 hex)
Input register start address0 (0x0000 hex)
Output Data Sizemax. 1024 register

EtherNet/IP™

Addressingacc. to EtherNet/IP specification
Input Data Size248 INT
Output Data Size248 INT
Device Level Ring (DLR)not supported

PROFINET

AddressingDCP
Diagnosticsacc. to PROFINET alarm handling
Input Data Sizemax. 512 BYTE
Topology detectionsupported
Ambient temperaturefrom -25 to 70 °C
Dimensions (L x W x H)74 x 145 x 77.5 mm
MinCycleTime1 ms
Automatic addressingsupported
Output Data Sizemax. 512 BYTE
Media Redundancy Protocol (MRP)not supported
Conformance classB (RT)