Turck

Turck
Compact multiprotocol I/O module for Ethernet 8 IO-Link Master Channels 4 Universal Digital PNP Channels, 2 A, Channel Diagnostics
SKU: 100003910 Type: TBEN-LL-8IOL
Available3–5 business days delivery
€435.70 / pieces
€518.48 incl. VAT
These are our list prices.Get an individual quote within 24 h.
Request a quoteFeatures
- PROFINET device, EtherNet/IP device, Modbus TCP server, CC-Link IE field basic
- Integrated Ethernet switch
- Supports 10 Mbps/100 Mbps
- 2 × M12, 4-pin, D-coded, Ethernet fieldbus connection
- PROFINET S2 system redundancy
- Glass fiber reinforced housing
- Shock and vibration tested
- Fully potted module electronics
- Protection classes IP65, IP67, IP69K
- M12, 5-pin, L-coded male connector for power supply
- Galvanically isolated voltage groups support passive safety
- ATEX zone 2/22
- CCC-Ex
- M12 ports for IO-Link master, 5-pin
- IO-Link master port class A and port class B
- IO-Link Protocol 1.1
- Programmable ARGEE
EtherNet/IP™
| Class 3 connections (TCP) | 3 TCP |
| Addressing | acc. to EtherNet/IP specification |
| Configuration Assembly Instance | 106 |
| Quick Connect (QC) | < 150 ms |
| Output Assembly Instance | 102 |
| Input Assembly Instance | 101 |
| min. RPI | 2 ms |
| Class 1 connections (CIP) | 10 CIP |
| Device Level Ring (DLR) | supported |
General Information
| Mounting | 2 mounting holes 6.3 mm |
| ERR | Green On No diagnostics available |
| ERR | Red On Diagnostics available |
| ERR | Undervoltage diagnosis response is parameter-dependent |
| MTTF | 160 years acc. to SN 29500 (Ed. 99) 20 °C |
| Halogen free | yes |
| L/A | Green On Ethernet link (100 Mbps) |
| L/A | Flashing Ethernet communication (100 Mbps) |
| L/A | Yellow On Ethernet link (10 Mbps) |
| L/A | Flashing Ethernet communication (10 Mbps) |
| L/A | Off No Ethernet link |
| Ambient temperature | from -40 to 70 °C |
| Connector material | Nickel-plated brass |
| Material screw | 303 stainless steel |
| Dimensions (L x W x H) | 60.4 x 230.4 x 34.8 mm |
| Housing colour | Black |
| Storage temperature | from -40 to 85 °C |
| PWR | LED response parameter (PWR) at V undervoltage = "red" |
| PWR | 2 |
| PWR | Green On V and V power supply OK |
| PWR | 1 2 |
| PWR | Red On V power supply off or V undervoltage |
| PWR | 2 2 |
| PWR | Off V power supply off or V undervoltage |
| PWR | 1 1 |
| PWR | LED response parameter (PWR) at V undervoltage = "green" |
| PWR | Flashing V power supply off or V undervoltage |
| Window material | Lexan |
| Altitude | Max. 5000 m |
| LED | Color Status Description |
| Housing material | PA6-GF30 |
| Material label | Polycarbonate |
| BUS | Green On Active connection to a client |
| BUS | Flashing Steady flashing: ready for operation |
| BUS | Sequence of 3 flashes in 2 seconds: FLC/ARGEE active |
| BUS | Red On IP address conflict or Restore mode or Modbus timeout |
| BUS | Flashing Blink/Wink command active |
| BUS | Green/red Alternating Autonegotiation and/or waiting for DHCP/Boot-P addressing |
| BUS | Off Power off |
| Degree of protection (IP) | IP67 |
| Degree of protection (IP) | IP69K |
| Degree of protection (IP) | IP65 |
Digital outputs
| Output current per channel | 2 A, short-circuit proof |
| Number of channels | 4 DXP |
| Output voltage | 24 VDC from potential group |
| Output type | PNP |
| Type of output diagnostics | Channel diagnostics |
| Output connectivity | M12, 5-pin |
LED Status I/O
| LED 1, 3, 5, 7 DXP | Green On Digital input or output active |
| LED 1, 3, 5, 7 DXP | Red On Output active with overload/short circuit |
| LED 1, 3, 5, 7 DXP | Flashing Overload supply VAUX 1 |
| LED 1, 3, 5, 7 DXP | Off Input or output inactive |
| IO-Link Class B VAUX2 | AUX2 |
| IO-Link Class B VAUX2 | Red On V active on Pin 2 with overload/short circuit |
| IO-Link Class B VAUX2 | Flashing Overload supply VAUX 1 |
| IO-Link Class B VAUX2 | Off V inactive on Pin 2 |
| LED 9, 11, 13, 15 | Green On V active on Pin 2 |
Digital inputs
| Switching threshold | SIO: EN 61131-2 type 1, PNPDXP: EN 61131-2 type 3, PNP |
| Number of channels | 4 DXP + 8 SIO |
| Input delay | 0.05 ms |
| Low level signal current | < 1.5 mA |
| Low-level signal voltage | < 5 V |
| Electrical isolation | Galvanically isolated to the fieldbus |
| Electrical isolation | voltages up to 500 VAC |
| High level signal current | > 2 mA |
| Input type | PNP |
| Type of input diagnostics | Channel diagnostics |
| High level signal voltage | > 11 V |
| Connectivity inputs | M12, 5-pin |
PROFINET
| Version | 2.35 |
| Addressing | DCP |
| Diagnostics | acc. to PROFINET alarm handling |
| Network load class | 3 |
| Topology detection | supported |
| Fast Start-Up (FSU) | < 150 ms |
| MinCycleTime | 1 ms |
| Automatic addressing | supported |
| System redundancy | S2 |
| Media Redundancy Protocol (MRP) | supported |
| Conformance class | B (RT) |
System data
| ARGEE functionality | Supported |
| Protocol detection | automatic |
| Transmission rate fieldbus | 10/100 Mbps |
| Service interface | Ethernet via XF1 or XF2 |
| Connection technology fieldbus | 2 × M12, 4-pin, D-coded |
IO-Link
| Transmission rate | 4.8 kbps (COM 1) / 38.4 kbps (COM 2) / 230 kbps |
| Transmission rate | (COM 3) |
| Number of channels | 8 |
| IO-Link port type | Class A and Class B |
| Frame type | Supports all specified frame types |
| IO-Link | Pin 4 in IOL mode |
| Supported devices | Max. 32 bytes in/32 bytes out per port |
| IO-Link specification | V 1.1 |
Modbus TCP
| Addressing | Static IP, DHCP |
| Number of TCP connections | 8 |
| Supported function codes | FC1, FC2, FC3, FC4, FC6, FC15, FC16, FC23 |
| Output register start address | 2048 (0x0800 hex) |
| Input register start address | 0 (0x0000 hex) |
CC-Link
| Acyclic SLMP communication | Yes |
| Interfaces | CC-Link IE Field Basic |
| IP change mechanism | Yes |
| Message Transmission | Yes |
| Max. occupied stations | 4 |
| Profile specification | CSP+ |
Supply
| Admissible range | 18…30 VDC Pass-through current XD1–XD2 max. |
| Admissible range | 16 A per voltage group Total current max. 9 A per |
| Admissible range | voltage group Total current V1 + V2 max. 11 A |
| Fault exclusion | Yes, acc. to EN ISO 13849-2, appendix D.2 |
| Sensor/actuator supply | Supply from V1 |
| Sensor/actuator supply | Short-circuit proof, max. 4 A per slot X0 and X4, |
| Sensor/actuator supply | max. 2 A per slot X1–X3, X5–X7 |
| Sensor/actuator supply | Class B supply from V2 |
| Sensor/actuator supply | Short-circuit proof, max. 4 A per slot X4 and X5, |
| Sensor/actuator supply | max. 2 A per slot X6 and X7 |
| Electrical isolation | galvanic isolation of the voltage groups V1 and V2, |
| Operating current | V1: max. 180 mA, min. 120 mA |
| Operating current | V2: min. 40 mA, max. 90 mA |
| Supply voltage | 24 VDC |
| Connection technology power supply | M12, L-coded |
Standard/Directive conformity
| Shock test | acc. to EN 60068-2-27 |
| Approvals and certificates | CEUKCAATEX zone 2/22 |
| Approvals and certificates | CCC-Ex |
| Approvals and certificates | FCC statement, |
| Approvals and certificates | UV resistant acc. to DIN EN ISO 4892-2A (2013) |
| Vibration test | Acc. to EN 60068-2-6 |
| Vibration test | Acceleration up to 20 g |
| UL Certificate | cULus LISTED 21 W2, Encl.Type 1 IND.CONT.EQ. |
| Drop and topple | acc. to EN 60068-2-31/IEC 60068-2-32 |
| Note on ATEX/IECEx | The Quick Start Guide with information on use in Ex |
| Note on ATEX/IECEx | areas must be observed. |
| Electromagnetic compatibility (EMC) | Acc. to EN 61131-2 |
Power supply
| Supply voltage | 24 VDC |
Other
| Housing material | Kunststoff |