HomeSensor AnalyticsFieldbus Modules100003910
TurckCompact multiprotocol I/O module for Ethernet 8 IO-Link Master Channels 4 Universal Digital PNP Channels, 2 A, Channel Diagnostics – Image 1
Turck

Compact multiprotocol I/O module for Ethernet 8 IO-Link Master Channels 4 Universal Digital PNP Channels, 2 A, Channel Diagnostics

SKU: 100003910 Type: TBEN-LL-8IOL
Available3–5 business days delivery
€435.70 / pieces
€518.48 incl. VAT

These are our list prices.Get an individual quote within 24 h.

Request a quote
Data sheet

Features

  • PROFINET device, EtherNet/IP device, Modbus TCP server, CC-Link IE field basic
  • Integrated Ethernet switch
  • Supports 10 Mbps/100 Mbps
  • 2 × M12, 4-pin, D-coded, Ethernet fieldbus connection
  • PROFINET S2 system redundancy
  • Glass fiber reinforced housing
  • Shock and vibration tested
  • Fully potted module electronics
  • Protection classes IP65, IP67, IP69K
  • M12, 5-pin, L-coded male connector for power supply
  • Galvanically isolated voltage groups support passive safety
  • ATEX zone 2/22
  • CCC-Ex
  • M12 ports for IO-Link master, 5-pin
  • IO-Link master port class A and port class B
  • IO-Link Protocol 1.1
  • Programmable ARGEE

EtherNet/IP™

Class 3 connections (TCP)3 TCP
Addressingacc. to EtherNet/IP specification
Configuration Assembly Instance106
Quick Connect (QC)< 150 ms
Output Assembly Instance102
Input Assembly Instance101
min. RPI2 ms
Class 1 connections (CIP)10 CIP
Device Level Ring (DLR)supported

General Information

Mounting2 mounting holes ￿ 6.3 mm
ERRGreen On No diagnostics available
ERRRed On Diagnostics available
ERRUndervoltage diagnosis response is parameter-dependent
MTTF160 years acc. to SN 29500 (Ed. 99) 20 °C
Halogen freeyes
L/AGreen On Ethernet link (100 Mbps)
L/AFlashing Ethernet communication (100 Mbps)
L/AYellow On Ethernet link (10 Mbps)
L/AFlashing Ethernet communication (10 Mbps)
L/AOff No Ethernet link
Ambient temperaturefrom -40 to 70 °C
Connector materialNickel-plated brass
Material screw303 stainless steel
Dimensions (L x W x H)60.4 x 230.4 x 34.8 mm
Housing colourBlack
Storage temperaturefrom -40 to 85 °C
PWRLED response parameter (PWR) at V undervoltage = "red"
PWR2
PWRGreen On V and V power supply OK
PWR1 2
PWRRed On V power supply off or V undervoltage
PWR2 2
PWROff V power supply off or V undervoltage
PWR1 1
PWRLED response parameter (PWR) at V undervoltage = "green"
PWRFlashing V power supply off or V undervoltage
Window materialLexan
AltitudeMax. 5000 m
LEDColor Status Description
Housing materialPA6-GF30
Material labelPolycarbonate
BUSGreen On Active connection to a client
BUSFlashing Steady flashing: ready for operation
BUSSequence of 3 flashes in 2 seconds: FLC/ARGEE active
BUSRed On IP address conflict or Restore mode or Modbus timeout
BUSFlashing Blink/Wink command active
BUSGreen/red Alternating Autonegotiation and/or waiting for DHCP/Boot-P addressing
BUSOff Power off
Degree of protection (IP)IP67
Degree of protection (IP)IP69K
Degree of protection (IP)IP65

Digital outputs

Output current per channel2 A, short-circuit proof
Number of channels4 DXP
Output voltage24 VDC from potential group
Output typePNP
Type of output diagnosticsChannel diagnostics
Output connectivityM12, 5-pin

LED Status I/O

LED 1, 3, 5, 7 DXPGreen On Digital input or output active
LED 1, 3, 5, 7 DXPRed On Output active with overload/short circuit
LED 1, 3, 5, 7 DXPFlashing Overload supply VAUX 1
LED 1, 3, 5, 7 DXPOff Input or output inactive
IO-Link Class B VAUX2AUX2
IO-Link Class B VAUX2Red On V active on Pin 2 with overload/short circuit
IO-Link Class B VAUX2Flashing Overload supply VAUX 1
IO-Link Class B VAUX2Off V inactive on Pin 2
LED 9, 11, 13, 15Green On V active on Pin 2

Digital inputs

Switching thresholdSIO: EN 61131-2 type 1, PNPDXP: EN 61131-2 type 3, PNP
Number of channels4 DXP + 8 SIO
Input delay0.05 ms
Low level signal current< 1.5 mA
Low-level signal voltage< 5 V
Electrical isolationGalvanically isolated to the fieldbus
Electrical isolationvoltages up to 500 VAC
High level signal current> 2 mA
Input typePNP
Type of input diagnosticsChannel diagnostics
High level signal voltage> 11 V
Connectivity inputsM12, 5-pin

PROFINET

Version2.35
AddressingDCP
Diagnosticsacc. to PROFINET alarm handling
Network load class3
Topology detectionsupported
Fast Start-Up (FSU)< 150 ms
MinCycleTime1 ms
Automatic addressingsupported
System redundancyS2
Media Redundancy Protocol (MRP)supported
Conformance classB (RT)

System data

ARGEE functionalitySupported
Protocol detectionautomatic
Transmission rate fieldbus10/100 Mbps
Service interfaceEthernet via XF1 or XF2
Connection technology fieldbus2 × M12, 4-pin, D-coded

IO-Link

Transmission rate4.8 kbps (COM 1) / 38.4 kbps (COM 2) / 230 kbps
Transmission rate(COM 3)
Number of channels8
IO-Link port typeClass A and Class B
Frame typeSupports all specified frame types
IO-LinkPin 4 in IOL mode
Supported devicesMax. 32 bytes in/32 bytes out per port
IO-Link specificationV 1.1

Modbus TCP

AddressingStatic IP, DHCP
Number of TCP connections8
Supported function codesFC1, FC2, FC3, FC4, FC6, FC15, FC16, FC23
Output register start address2048 (0x0800 hex)
Input register start address0 (0x0000 hex)

CC-Link

Acyclic SLMP communicationYes
InterfacesCC-Link IE Field Basic
IP change mechanismYes
Message TransmissionYes
Max. occupied stations4
Profile specificationCSP+

Supply

Admissible range18…30 VDC Pass-through current XD1–XD2 max.
Admissible range16 A per voltage group Total current max. 9 A per
Admissible rangevoltage group Total current V1 + V2 max. 11 A
Fault exclusionYes, acc. to EN ISO 13849-2, appendix D.2
Sensor/actuator supplySupply from V1
Sensor/actuator supplyShort-circuit proof, max. 4 A per slot X0 and X4,
Sensor/actuator supplymax. 2 A per slot X1–X3, X5–X7
Sensor/actuator supplyClass B supply from V2
Sensor/actuator supplyShort-circuit proof, max. 4 A per slot X4 and X5,
Sensor/actuator supplymax. 2 A per slot X6 and X7
Electrical isolationgalvanic isolation of the voltage groups V1 and V2,
Operating currentV1: max. 180 mA, min. 120 mA
Operating currentV2: min. 40 mA, max. 90 mA
Supply voltage24 VDC
Connection technology power supplyM12, L-coded

Standard/Directive conformity

Shock testacc. to EN 60068-2-27
Approvals and certificatesCEUKCAATEX zone 2/22
Approvals and certificatesCCC-Ex
Approvals and certificatesFCC statement,
Approvals and certificatesUV resistant acc. to DIN EN ISO 4892-2A (2013)
Vibration testAcc. to EN 60068-2-6
Vibration testAcceleration up to 20 g
UL CertificatecULus LISTED 21 W2, Encl.Type 1 IND.CONT.EQ.
Drop and toppleacc. to EN 60068-2-31/IEC 60068-2-32
Note on ATEX/IECExThe Quick Start Guide with information on use in Ex
Note on ATEX/IECExareas must be observed.
Electromagnetic compatibility (EMC)Acc. to EN 61131-2

Power supply

Supply voltage24 VDC

Other

Housing materialKunststoff