Turck
Turck
Compact Multiprotocol I/O Module for Ethernet 4 IO-Link Master Channels 4 Universal Digital PNP Channels, 0.5 A, Channel Diagnostics
SKU: 6814024 Type: TBEN-S2-4IOL
Available 3–5 business days delivery
€298.70 / pieces
€355.45 incl. VAT
Features
- • PROFINET device, EtherNet/IP device, Modbus TCP server, CC-Link IE field basic
- • Integrated Ethernet switch
- • Supports 10 Mbps/100 Mbps
- • 2 × M8, 4-pin, Ethernet fieldbus connection
- • PROFINET S2 system redundancy
- • Glass fiber reinforced housing
- • Shock and vibration tested
- • Fully potted module electronics
- • Protection classes IP65, IP67, IP69K
- • 4-pin M8 male connector for power supply
- • Galvanically isolated voltage groups
- • ATEX zone 2/22
- • CCC-Ex
- • M12 ports for IO-Link master, 5-pin
- • IO-Link Protocol 1.1
- • Programmable ARGEE
EtherNet/IP™
| Class 3 connections (TCP) | 3 TCP |
| Addressing | acc. to EtherNet/IP specification |
| Configuration Assembly Instance | 106 |
| Quick Connect (QC) | < 500 ms |
| Output Assembly Instance | 104 |
| Input Assembly Instance | 103 |
| min. RPI | 2 ms |
| Class 1 connections (CIP) | 10 CIP |
| Device Level Ring (DLR) | supported |
General Information
| Mounting | 2 mounting holes 4.6 mm |
| Mounting | Note the numbering of the IO range: |
| Mounting | From firmware version 3.1.10.0 and higher ports C0 |
| Mounting | to C3 and channels CH0 to CH3 are counted. For |
| Mounting | more details on the corresponding change see manual. |
| ERR | Green On No diagnostics available |
| ERR | Red On Diagnostics available |
| ERR | Undervoltage diagnosis response is parameter dependent |
| MTTF | 260 years acc. to SN 29500 (Ed. 99) 20 °C |
| Halogen free | yes |
| Ambient temperature | from -40 to 70 °C |
| Connector material | Nickel-plated brass |
| Dimensions (L x W x H) | 32 x 144 x 32 mm |
| Housing colour | Black |
| ETH1/ETH2 | Green ON Ethernet link (100 Mbps) |
| ETH1/ETH2 | flashing Ethernet communication (100 Mbps) |
| ETH1/ETH2 | Yellow ON Ethernet link (10 Mbps) |
| ETH1/ETH2 | flashing Ethernet communication (10 Mbps) |
| ETH1/ETH2 | OFF No Ethernet link |
| Storage temperature | from -40 to 85 °C |
| PWR | Green On V and V power supply OK |
| PWR | 1 2 |
| PWR | Red On V power supply off or V undervoltage |
| PWR | 2 2 |
| PWR | Off V power supply off or V undervoltage |
| PWR | 1 1 |
| Altitude | Max. 5000 m |
| LED | Color Status Description |
| Housing material | PA6-GF30 |
| Material label | Polycarbonate |
| BUS | Green ON Active connection to a master |
| BUS | Flashing Steady flashing: Ready |
| BUS | Sequence of 3 flashes in 2 seconds: FLC/ARGEE active |
| BUS | Red ON IP address conflict or Restore Mode or Modbus timeout |
| BUS | Flashing Blink/Wink command active |
| BUS | Red/ Alternating Waiting for assignment of an IP address, DHCP or BootP |
| BUS | Green |
| BUS | OFF Power off |
| Degree of protection (IP) | IP67 |
| Degree of protection (IP) | IP69K |
| Degree of protection (IP) | IP65 |
EtherNet/IP data mapping
| Diag 0x0045 | GEN- OVL VHIGH VLOW ULVE LLVU OTMP PRMEREVT1 EVT2 PDINV HWER DSER CFGERPPE - |
| Diag 0x0044 | GEN- OVL VHIGH VLOW ULVE LLVU OTMP PRMEREVT1 EVT2 PDINV HWER DSER CFGERPPE - |
| Output data (scanner -> stati | on) |
| Status (RO) | 0x94 LSB - FCE - - - - V1 - V2 - - - - - - DIAG |
| Status (RO) | 0x95 MSB |
| Inputs (RO) 0x0001 | - - - - - - - - DXP7 SIO6 DXP5 SIO4 DXP3 SIO2 DXP1 SIO0 |
| Inputs (RO) 0x0001 | C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 |
| PROFINET Register Mappin | g |
| PROFINET Register Mappin | MSB LSB |
| Outputs (RO) 0x0001 | - - - - - - - - DXP7 - DXP5 - DXP3 - DXP1 - |
| Outputs (RO) 0x0001 | C3P2 C2P2 C1P2 C0P2 |
| Input data (station -> scanne | r) |
| Inputs (RO) 0x00 LSB | - - - - - - - - DXP7 SIO6 DXP5 SIO4 DXP3 SIO2 DXP1 SIO0 |
| Outputs | 0x00 LSB - - - - - - - - DXP7 - DXP5 - DXP3 - DXP1 - |
| Outputs | 0x01 MSB C3P2 C2P2 C1P2 C0P2 |
| Outputs | 0x02 LSB - - - - - - - - - - - - - - - - |
| Outputs | 0x03 MSB |
| Outputs | 0x04 LSB IO-Link Port 1 |
| Outputs | … Byte 0…31 |
| Outputs | 0x23 MSB |
| Outputs | 0x24 LSB IO-Link Port 2 |
| Outputs | 0x43 MSB |
| Outputs | 0x44 LSB IO-Link Port 3 |
| Outputs | 0x63 MSB |
| Outputs | 0x64 LSB IO-Link Port 4 |
| Outputs | 0x83 MSB |
| Diag 0x92 LSB DXP 0x93 MSB | - - - - - - - - ERR7 - ERR5 - ERR3 - ERR1 - |
| Diag 0x92 LSB DXP 0x93 MSB | 0x96 LSB eventCode MSB eventCode LSB |
| Diag 0x92 LSB DXP 0x93 MSB | 0x97 MSB |
| Diag 0x92 LSB DXP 0x93 MSB | … |
| Diag 0x92 LSB DXP 0x93 MSB | 0xCA LSB Port Qualifier |
| Diag 0x92 LSB DXP 0x93 MSB | 0xCB MSB |
| Diag 0x92 LSB DXP 0x93 MSB | 0xCC LSB eventCode MSB eventCode LSB |
| Diag 0x92 LSB DXP 0x93 MSB | 0xCD MSB |
Digital outputs
| Output current per channel | 0.5 A, short-circuit proof |
| Number of channels | 4 DXP |
| Output voltage | 24 VDC from potential group |
| Electrical isolation | galvanic isolation to P1/P2 |
| Electrical isolation | voltages up to 500 VDC |
| Output type | PNP |
| Type of load | resistive, inductive, lamp load |
| Type of output diagnostics | Channel diagnostics |
| Output connectivity | M12, 5-pin |
System data
| Web server | default: 192.168.1.254 |
| ARGEE functionality | Supported |
| Protocol detection | automatic |
| Transmission rate fieldbus | 10/100 Mbps |
| Service interface | Ethernet via P1 or P2 |
| Connection technology fieldbus | 2 × M8, 4-pin |
Digital inputs
| Switching threshold | SIO: EN 61131-2 type 1, PNPDXP: EN 61131-2 type 3, PNP |
| Number of channels | 4 DXP + 4 SIO |
| Low level signal current | < 1.5 mA |
| Low-level signal voltage | < 5 V |
| Electrical isolation | galvanic isolation to the bus |
| Electrical isolation | voltages up to 500 VAC |
| High level signal current | > 2 mA |
| Input type | PNP |
| Type of input diagnostics | Channel diagnostics |
| High level signal voltage | > 11 V |
| Connectivity inputs | M12, 5-pin |
PROFINET
| Version | 2.35 |
| Addressing | DCP |
| Diagnostics | acc. to PROFINET alarm handling |
| Network load class | 3 |
| Topology detection | supported |
| Fast Start-Up (FSU) | < 500 ms |
| MinCycleTime | 1 ms |
| Automatic addressing | supported |
| System redundancy | S2 |
| Media Redundancy Protocol (MRP) | supported |
| Conformance class | B (RT) |
IO-Link
| Transmission rate | 4.8 kbps (COM 1) / 38.4 kbps (COM 2) / 230 kbps |
| Transmission rate | (COM 3) |
| Number of channels | 4 |
| IO-Link port type | Class A |
| Frame type | supports all specified frame types |
| IO-Link | Pin 4 in IOL mode |
| Supported devices | Max. 32 bytes in/32 bytes out per port |
| IO-Link specification | V 1.1 |
Modbus TCP
| Addressing | Static IP, DHCP |
| Number of TCP connections | 8 |
| Supported function codes | FC1, FC2, FC3, FC4, FC6, FC15, FC16, FC23 |
| Output register start address | 2048 (0x0800 hex) |
| Input register start address | 0 (0x0000 hex) |
Supply
| Sensor/actuator supply | supply of ports C0-C3 from V2 |
| Sensor/actuator supply | not short-circuit proof, max. 4 A per group C0-C3 |
| Admissible range | 18…30 VDC |
| Admissible range | Total current max. 4A per voltage group |
| Electrical isolation | galvanic isolation of the voltage groups V1 and V2, |
| Operating current | V1: min. 50 mA, max. 110 mA |
| Operating current | V2: min. 10 mA, max. 115 mA |
| Supply voltage | 24 VDC |
| Connection technology power supply | 2 × M8, 4-pin, A-coded |
CC-Link
| Acyclic SLMP communication | Yes |
| Interfaces | CC-Link IE Field Basic |
| IP change mechanism | Yes |
| Message Transmission | Yes |
| Max. occupied stations | 4 |
| Profile specification | CSP+ |
LED Status I/O
| Outputs (RO) 0x0800 | - - - - - - - - DXP7 - DXP5 - DXP3 - DXP1 - |
| Outputs (RO) 0x0800 | C3P2 C2P2 C1P2 C0P2 |
| Diag 0x0045 | GEN- OVL VHIGH VLOW ULVE LLVU OTMP PRMEREVT2 EVT1 PDINV HWER DSER CFGERPPE - |
| Diag 0x0043 | GEN- OVL VHIGH VLOW ULVE LLVU OTMP PRMEREVT2 EVT1 PDINV HWER DSER CFGERPPE - |
| Diag 0x0044 | GEN- OVL VHIGH VLOW ULVE LLVU OTMP PRMEREVT2 EVT1 PDINV HWER DSER CFGERPPE - |
| Diag 0x0042 | GEN- OVL VHIGH VLOW ULVE LLVU OTMP PRMEREVT2 EVT1 PDINV HWER DSER CFGERPPE - |
| 0x0022 … 0x0031 | IO-Link Port 3 |
| 0x0022 … 0x0031 | Byte 0…31 |
| 0x0012 … 0x0021 | IO-Link Port 2 |
| 0x0012 … 0x0021 | Byte 0…31 |
| 0x0032 … 0x0041 | IO-Link Port 4 |
| 0x0032 … 0x0041 | Byte 0…31 |
| Inputs (RO) 0x0000 | - - - - - - - - DXP7 SIO6 DXP5 SIO4 DXP3 SIO2 DXP1 SIO0 |
| Inputs (RO) 0x0000 | C3P2 C3P4 C2P2 C2P4 C1P2 C1P4 C0P2 C0P4 |
| Status (RO) 0x0067 | FCE V1 V2 DIAG |
| DXP 1, 3, 5, 7 | Green ON Digital input or output active |
| DXP 1, 3, 5, 7 | Red ON Output active with overload/short circuit |
| DXP 1, 3, 5, 7 | OFF Input or output inactive |
| 0x0801 … 0x0810 | IO-Link Port 1 |
| 0x0801 … 0x0810 | Byte 0…31 |
| 0x0801 … 0x0810 | IO-Link Port 2 |
| 0x0801 … 0x0810 | IO-Link Port 3 |
| 0x0801 … 0x0810 | IO-Link Port 4 |
| 0x0002 … 0x0011 | IO-Link Port 1 |
| 0x0002 … 0x0011 | Byte 0…31 |
| DXP 7 | White Flashing Supports blink/wink commands |
| Port4 | ER |
| Port2 | ER |
| Port3 | ER |
| Port1 | ER |
| 0x0001… | - - - - - - - - - DVS7 - DVS5 - DVS3 - DVS1 |
| Reg | Bit 15 Bit 14 Bit 13 Bit 12 Bit 11 Bit 10 Bit 9 Bit 8 Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 |
| Diag 0x0046 DXP | - - - - - - - - ERR7 - ERR6 - ERR4 - ERR1 - |
Standard/Directive conformity
| Shock test | acc. to EN 60068-2-27 |
| Approvals and certificates | CEUKCAATEX zone 2/22 |
| Approvals and certificates | CCC-Ex |
| Approvals and certificates | FCC statement, |
| Approvals and certificates | UV resistant acc. to DIN EN ISO 4892-2A (2013) |
| Vibration test | Acc. to EN 60068-2-6 |
| Vibration test | Acceleration up to 20 g |
| UL Certificate | cULus LISTED 21 W2, Encl.Type 1 IND.CONT.EQ. |
| Drop and topple | acc. to EN 60068-2-31/IEC 60068-2-32 |
| Note on ATEX/IECEx | The Quick Start Guide with information on use in Ex |
| Note on ATEX/IECEx | areas must be observed. |
| Electromagnetic compatibility (EMC) | Acc. to EN 61131-2 |
Power supply
| Supply voltage | 24 VDC |