HomeSensor AnalyticsIO-Link6825482
TurckIO-Link Master v1.1 with Integrated USB Port 1-Channel Operation in IOL or SIO Mode – Image 1
Turck

IO-Link Master v1.1 with Integrated USB Port 1-Channel Operation in IOL or SIO Mode

SKU: 6825482 Type: USB-2-IOL-0002
Available3–5 business days delivery
€281.40 / pieces
€334.87 incl. VAT

These are our list prices.Get an individual quote within 24 h.

Request a quote
Data sheet

Features

  • USB-compatible IO-Link master
  • Commissioning/parameterization of IOLink devices via FDT/DTM
  • Control environment not required
  • Transmission of process and service data
  • Integrated connectors: USB/B, M12 × 1, power supply
  • Power supply via USB or external power supply unit (included in set)
  • Compact aluminum housing
  • Protection class IP40 M12 × 1

Functional principle

IO-Link devices are easily put into operation with the IO-Link master 1.1. Commissioning of IO-Link devices, reading of process data (PD) and reading/writing of specified service data (SD) is possible, independently from the higher-level control. Pin 4 (C/Q) of the IO-Link master can be operated either in the IO-Link mode (IOL) or in the standard IO mode (SIO), depending on the DTM parametrization. The following transmission rates are possible 4.8 kbps (COM1), 38.4 kbps (COM2) and 230.4 kbps (COM3). Depending on the connected IO-link device, data back-up via an integrated parametrizing server is also supported. Easy connection to PC via USB port. Latest DTM version available for download on www.turck.com. IO-Link devices are directly supplied via the integrated mini USB port. In the event of increased current consumption, the connected devices should be supplied by the external plug-in power unit.

Mechanical data

CH1(C/Q)green off SIO mode active
CH1(C/Q)slowly flashing IO-Link Scan Mode active, no communication
CH1(C/Q)fast flashing IO-Link Preoperate Mode active
CH1(C/Q)on IO-Link Operate Mode active
CH1(C/Q)yellow off low signal at port 1
CH1(C/Q)on high signal at port 1
CH2(DI/DO)yellow off low signal at port 2
CH2(DI/DO)on high signal at port 2
Errorred off no error
Erroron short-circuit, overload, communication error
Ambient temperaturefrom -5 to 55 °C
Weightapprox. 0.096 kg
Storage temperaturefrom -25 to 70 °C
PWRyellow off power off
PWRflashing undervoltage, overload with power suppy via USBon ready
LEDColor Status Description
Degree of protection (IP)IP40
Abmessung54 x 41 x 24 mm

Electrical data

Network connectionUSB-B
IO-Link portM12 × 1, A-coded
Max. load current above IO-Link port40 mA via USB-B (1.6 A via plug-in power supply)
Supply voltage24 VDC

IO-Link

Number of IO-Link ports1
FunctionSIO, COM1, COM2, COM3
IO-Link1-channel operation in IOL or SIO mode
NetworkUSB