HomePosition SensorsCapacitive Sensors100004248
Turck Capacitive Limit Level Sensor – Image 1
Turck

Capacitive Limit Level Sensor

SKU: 100004248 Type: NCLS-30-UP6X-H1141
Available 3–5 business days delivery
€202.30 / pieces
€240.74 incl. VAT
Data sheet

Features

  • Media-contacting detection of limit levels in tanks and pipes
  • Detection of different substances (liquid, viscous, granular, powder form)
  • Hygienic PEEK tip, CIP/SIP compatible
  • EHEDG certified (with NCLS-WA1 process adapter)
  • Highly visible ring LED
  • 12…32 VDC, power consumption: typically 1 W, max. 3 W
  • Two digital outputs, separately adjustable as NO/NC
  • PNP, NPN or push-pull, switchable
  • IO-Link for parameterization/process values
  • Process connection G1/2" male thread, hygienic (in combination with TURCK adapters)
  • 4-pin connector device, M12 × 1

Functional principle

Capacitive proximity switches are designed for wear-free detection of metal (electrically conductive) as well as non-metal (not electrically conductive) objects. A key feature of the NCLS limit level sensors is the ability to detect and differentiate between various liquids, viscous materials, granular materials and powders by making contact with the media. They are extremely well suited for detecting level limits (max./min.) and changes to the media in tanks and pipelines.

Mechanical data

Display switch state Ring LED, Green, (Reverse of operating
Display switch state voltage indicator)
Display operating voltage Ring LED, Green
Vibration resistance 2 Hz (1 mm)
MTTF 1080 years acc. to SN 29500 (Ed. 99) 40
MTTF °C
Elektrischer Anschluss Connector, M12 × 1
Process connection G 1/2" male thread, hygienic
Materials (media-contacting) Plastic, PEEK
Design Threaded barrel, G ½''
Max. tightening torque of housing nut 20 Nm
Housing material Stainless steel, 1.4404 (AISI 316L)
Shock resistance 7 g (11 ms)
Degree of protection (IP) IP67
Degree of protection (IP) IP69K
Abmessung 94.8 x 22 x 22 mm

Electrical data

SIO mode-compatible Yes
Wire break/reverse polarity protection yes/Complete
Isolation test voltage 0.5 kV
Switch-on time < 0.3 s
Switching frequency up to 5 Hz
Power consumption 3 W
Short circuit protection yes
Output function 4-wire, NO/NC, PNP
Communication protocol IO-Link
Number of digital outputs 2
Operating voltage UB from 12 to 32 VDC
Electrical safety class III
Ansprechzeit (bei ruhender Luft) < 0.2 s

Allgemein

Comment on the media temperature 0…+130 °C for < 1 h at an ambient temperature of 40 °C
Pressure resistance 10 bar
Required permittivity (εr) 1.5 εr
Installation information Please use the NCLS limit level sensor
Installation information only with original Turck process adapters!
Installation position any
Ambient temperature from -10 to 70 °C
Vacuum resistance -1 bar
Storage temperature from -20 to 70 °C
Medium temperature from 0 to 100 °C
CIP/SIP-capable yes

Programming FDT / DTM

Transmission rate COM 2/38.4 kbps
Transmission physics corresponds to 3-wire physics (PHY2)
Frame type 2.2
Process data width 16 bit
Included in the SIDI GSDML Yes
Switchpoint information 2 bit
Measured value information 14 bit

Tests/approvals

Approvals CE
Approvals EHEDG

IO-Link

IO-Link specification V 1.1