Processor Unit – For the Connection of FCS and FCI Product Series Flow Sensors IO-Link Device with Relay Switching Outputs

SKU: 7525102 Type: FM-IM-3UR38X
Available 3–5 business days delivery
€281.90 / pieces
€335.46 incl. VAT
Data sheet

Features

  • Relay output for flow, temperature and faults
  • Adjustment of switchpoint, no teaching of flow boundaries (QuickTeach)
  • LED band for indication of flow speed and media temperature
  • Monitoring of operating and display range
  • Detection of wire-break and short-circuit on the sensor side
  • Standard IO or IO-Link operating mode
  • Parametrized via pushbutton or software-supported via IO-Link

Functional principle

All non-Ex flow sensors from the FCS series (immersion sensors) and FCI series (inline series) can be operated with the FM-IM external processing unit. The flow module features four status LEDs the standard way. In IOL mode the current process signal is transmitted cyclically as a 10 bit-serial value. Parametrization is initiated either via pushbutton or software-supported via IOLink interface. The actual parametrization is then implemented via the tool-based DTM or IODD within the FDT frame PACTware™ or acyclically near the control via On-Request Data Objects (ORDO).

Mechanical data

Flow yellow off Switching output flow [low]
Flow on Switching output flow [high]
Flow flashing Teach mode / display of diagnostic data
Flow for specification see manual
Flow Value 10 Bit (Bit 15 = MSB, Bit 6 = LSB) not assigned Out 3 Out 2 Out1
Flow (Fault) (Temp) (Flow)
Temp yellow off Switching output media temperature [low]
Temp on Switching output media temperature [high]
Temp flashing Teach mode / display of diagnostic data
Temp for specification see manual
MTBF 126 Years
Mounting method DIN rail mounting and mounting panel
Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
Ambient temperature from -25 to 70 °C
Design Signal processor
PWR green on Operating voltage applied
PWR Device ready for operation
PWR flashing Operating voltage applied
PWR IO-Link communication active
PWR (inverted flash with T on 900 ms and T off 100 ms)
LED displa y
LED Color Status Description
Housing material Plastic, Polycarbonate/ABS
Fault Red Off Switching output fault [high]
Fault On Switching output flow [low]
Fault (for error pattern in combination with LEDs see manual)
For detaile IM/FMX-IM IO-Link (Pr d description of the display patterns and flashing codes see instructi
For detaile IM/FMX-IM IO-Link (Pr ocess Data Objects)
Degree of protection (IP) IP20
Abmessung 89 x 110 x 27 mm

Customizable output functions

Display switch state NO/NC parametrizable (relay output error
Display switch state monitoring only NC)
Switching characteristic NO/NC
Switching voltage < 250 VAC / 60 VDC
Error monitoring relay output
Flow Monitoring relay output
Electrical connections 5-pole removable reverse polarity protected terminal blocks
Type of fastening screw connection
Temperature monitoring relay output
Switching frequency up to 10 Hz
Terminal cross-section ≥ 1.5…≤ 2.5 mm²
Switching current up to 2 A
Switching power up to 500 VA

IO-Link

Transmission rate 38.4 kBit/s (COM 2)
Communication modes Tool based engineering via FDT / DTM,
Communication modes IODD. Acyclic communication via On-Request Data Objects
Included in the SIDI GSDML Yes
Communication channel Jack plug COM (PC)
IO-Link specification V 1.0

Electrical data

Measurement frequency 5 Hz (every 200 ms with software filter)
Sensor current limitation approx. 110 mA
Repeatability media temperature typical ± 1 K
Medium temperature [°C] with the SET button temporarily
Medium temperature pressed
Measuring accuracy media temperature typical ± 7 K
Sensor current ≤ 35 mA
Sensor voltage ≤ 15 VDC
Frequency from 40 to 70 Hz
No-load current I0 ≤ 63 mA
Teach modes QuickTeach; min/max adjustment. Teach
Teach modes modes incl. DeltaFlow monitoring (teach
Teach modes modes are automatically released with
Teach modes the change of flow speed).
Input function Connection of flow sensors (non-Ex sensors of the FCS/FCI product series only!)
Flow speed [%] after min/max adjustment (permanent)
Flow speed % after Quick-Teach (permanent)
Switchpoint hysteresis media temperature 2 K
Operating voltage UB 20…250 VAC
Operating voltage UB 20…125 VDC
Repeatability flow rate typical ± 1 % (of full scale)
Power consumption up to 4 VA

Tests/approvals

Relative humidity EN 60068-2-38
Approvals CE
Approvals C-UL U.S. submitted
Electromagnetic compatibility (EMC) Acc. to NE21

ausgangsfunktionen

Switching frequency up to 10 Hz
Switching current up to 2 A
Switching power up to 500 VA