HomeProcess SensorsTemperature Sensors100002533
Turck TTM150C-206A-G1/2-LI6-H1140-L460-50/150C Temperature Detection – With Current Output – Image 1
Turck

TTM150C-206A-G1/2-LI6-H1140-L460-50/150C Temperature Detection – With Current Output

SKU: 100002533 Type: TTM150C-206A-G1/2-LI6-H1140- L460-50/150C
Available 3–5 business days delivery
€146.10 / pieces
€173.86 incl. VAT
Data sheet

Features

  • Miniature design
  • Analog output 4…20 mA
  • Factory setting -50…150 °C (other settings on request)
  • Process connection G1/2" male thread
  • Bendable probe (min. bending radius: 3x outer diameter; excluding 30-mm probe tip)

Functional principle

The TTM miniature transmitters are available with integrated probe. Due to the integrated electronics, the limited temperature range must be observed, especially in the area of the M12 connector.

Analog output

Load ≤ 0.84 kΩ at 24 VDC [R =(V –
Load Load Supply
Load 5.5 V)/22 mA]
Current output 4…20 mA
Accuracy ± 0.2 K

Reference conditions acc. to IEC 61298-1

Auxiliary power 24 VDC
Humidity from 45 to 75 %
Atmospheric pressure from 860 to 1060 hPa
Temperatur (-) 15…+25 °C

Power supply

Short-Circuit/Reverse Polarity Protection yes / yes
Electricity consumption up to 20 mA
Operating voltage UB from 5.5 to 32 VDC
Degree of protection (IP) IP67
Electrical safety class III

Temperature behaviour

Temperature coefficient zero point TK0 ± 0.1 % of full scale/10 K
Temperature coefficient range TKs ± 0.1 % of full scale/10 K

Tests/approvals

MTTF 162 years acc. to SN 29500 (Ed. 99) 40
MTTF °C

Mechanical data

Sensor material Stainless steel, 1.4404 (AISI 316L)
Elektrischer Anschluss Connector, M12 × 1
Pressure resistance 100 bar
Process connection G 1/2'' male thread
Housing material Stainless-steel/Plastic, 1.4404 (AISI
Housing material 316L)

Temperature range

Outer diameter 6 mm
Immersion depth L 460 mm
Note Max. temperature of electronics:
Note 80 °C/176 °F
Measuring range -50…150 °C
Measuring range -58…302 °F
Messelement (nach DIN IEC 751) Pt1000, DIN EN 60751, class A
Ansprechzeit (bei ruhender Luft) t₀₅ = 1.5 s / t₀₉ = 6.0 s in water @ 0.2 m/s

Ambient Conditions

Ambient temperature from -40 to 80 °C
Storage temperature from -40 to 80 °C