Ultrasonic Sensor – Retroreflective Sensor
Features
- • Smooth sonic transducer face
- • Cylindrical housing M08, potted
- • Connection via M8 × 1 male connector
- • Teach range adjustable via connection cable
- • Blind zone: 2 cm
- • Range: 10 cm
- • Resolution: 0.2 mm
- • Aperture angle of sonic cone: ±9 °
- • 1x switching output, PNP
- • Teachable settings
- • NO/NC programmable
- • IO-Link
Functional principle
Ultrasonic sensors capture a multitude of objects contactlessly and wear-free with ultrasonic waves. It does not matter whether the object is transparent or opaque, metallic or non-metallic, firm, liquid or powdery. Even environmental conditions such as spray, dust or rain hardly affect their function. The sonic cone diagram indicates the detection range of the sensor. In accordance with standard EN 60947-5-2, quadratic targets in a range of sizes (20 × 20 mm, 100 × 100 mm) and a round rod with a diameter of 27 mm are used. Important: The detection ranges for other targets may differ from those for standard targets due to the different reflection properties and geometries.
Electrical data
| Standby delay | ≤ 300 ms |
| Switching frequency | up to 20 Hz |
| Voltage drop at Ie | ≤ 2.5 V |
| Adjustment option | Remote Teach |
| Adjustment option | IO-Link |
| Hysteresis | ≤ 5 mm |
| Short circuit protection | yes |
| Polarity protection | yes |
| Output function | NO/NC, PNP |
| Output 1 | Switching output or IO-Link mode |
| Communication protocol | IO-Link |
| No-load current | up to 50 mA |
| Residual current | ≤ 0.1 mA |
| Operating voltage UB | from 18 to 30 VDC |
| Lastwiderstand (U-Ausgang) | ≤ 1000 Ω |
Mechanical data
| Display switch state | LED, Yellow |
| Elektrischer Anschluss | Connector, M8 × 1, 4-wire |
| Pressure resistance | 0.5…5 bar |
| Ambient temperature | from 0 to 50 °C |
| Storage temperature | from 0 to 50 °C |
| Transducer material | Plastic, Epoxyd resin and PU foam |
| Design | Threaded barrel, M08 |
| Housing material | Metal, CuZn, Nickel Plated |
| Degree of protection (IP) | IP67 |
| Abmessung | Ø 8 x 70 mm |
IO-Link
| Maximum Cable Length | 20 m |
| IO-Link port type | Class A |
| Communication mode | COM 2 (38.4 kBaud) |
| Function pin 4 | IO-Link |
| Frame type | 2.2 |
| Process data width | 16 bit |
| Minimum cycle time | 2 ms |
| Profile support | Smart Sensor Profile |
| Included in the SIDI GSDML | Yes |
| Switchpoint information | 1 bit |
| IO-Link specification | V 1.1 |
| Measured value information | 15 bit |
Tests/approvals
| MTTF | acc. to SN 29500 (Ed. 99) 40 °C |
| Declaration of conformity EN ISO/IEC | EN 60947-5-2 |
| Shock test | 30 g, 11 ms/10…55 Hz, 1.0 mm shock/vibration according to EN 60947-5-2 |
| Approvals | cULus |
| Approvals | CE |
Ultrasonic data
| Temperature drift | ≤ 0.2 % of full scale/K |
| Function | Retroreflective Sensor |
| Resolution | 0.2 mm |
| Approach speed | ≤ 1 m/s |
| Overrun Speed | ≤ 1 m/s |
| Ultrasound frequency | 484 kHz |
| Range | from 0.02 to 0.1 m |
| Minimum switching range | 5 mm |